In the event of negative weight, the first character on the left acquires the value « - » (minus sign - ASCII 45).
If the protocol on
has been set, the decimal point at the position shown on the instrument's display can also be
transmitted. In this case, if the value exceeds 5 digits, only the 5 most significant digits are transmitted, while if the value is
negative, no more than the 4 most significant digits are transmitted. In both cases, however, the decimal point shifts
consistently with the value to display.
If
has been set, in addition to what is stated in
protocol, the instrument transmits the prompt net every 4
seconds in the gross weight field, when the instrument is in net mode. See Section 3.1 on page 29.
In case weight value is under -99999, the minus sign (-) is sent alternated with the most significant figure.
In the event of error or alarm, the 6 characters of the gross and net weight are replaced by the messages found in
3.15 Interface to Remote Display
Remote Display (Laser Light)
1. Press and hold
, then press
.
is displayed.
2. Press or until
is displayed.
3. Press
.
is displayed.
4. Press
.
is displayed.
5. Press or until
is displayed. Press
.
6. Press
twice to exit set-up menu.
Laser Light
E CHAR = CR
LWPOS = 7
LENGTH = 19
Laser Light 1550
S CHAR = SoH
LWPOS = 000008
N
1 reference character for net weight. (78 ASCII)
xxxxxx
6 ASCII characters for net or peak weight if present (48 ÷ 57 ASCII)
L
1 reference character for gross weight (76 ASCII)
yyyyyy
6 ASCII characters for gross weight (48 ? 57 ASCII).
\
1 character for separation (92 ASCII)
ckck
2 ASCII control characters calculated considering that the characters between
&
and
\
are excluded
The control value is obtained by carrying out the XOR (or exclusive) operation for the 8 bit ASCII codes of the characters consid-
ered. character expressed in hexadecimal is thus obtained, with 2 digits which may acquire values from
0
to
9
and from
A
to
F
.
ckck
is the ASCII code of the two hexadecimal digits.
CR
character for string end (13 ASCII).
Data
Definition
Table 3-48. Continuous Transmission Protocol Data Definitions
Laser Light
SCT
Connector
Pin
Connector
J8 (RS-232)
3
RS-485 RX-
5
RS-485 RX+
Table 3-49. Laser Light Setup