Data Identifiers
Data Sent
Definition
$
Beginning of a request string (36 ASCII)
& o &&
Beginning of a response string (38 ASCII)
aa
2 characters for instrument address (48 ÷ 57 ASCII)
!
1 character to indicate the correct reception(33 ASCII
?
1 character to indicate a reception error (63 ASCII)
#
1 character to indicate an error in the command execution (23 ASCII)
ckck
2 ASCII characters for Check-Sum.
CR
1 character for string end (13 ASCII)
\
1 character for separation (92 ASCII)
Table 3-38. Data Identifiers (ASCII)
Setpoint Values Setting:
The PC transmits: $aaxxxxxxyckckCR in which:
Possible instrument responses:
• Correct reception: &&aa!\ckckCR
• Incorrect reception: &&aa?\ckckCR
Setpoints Storage Into EEPROM Memory:
The setpoints value relevant to the two setpoints programmed via the PC are stored to the RAM volatile memory and lost upon
instrument power off. It is necessary to send a special command to save them permanently in the EEPROM memory. Please
note that the number of writes allowed in the EEPROM memory is limited (about 100000).
The PC transmits: $aaMEMckckCR$01MEM44CR
Possible instrument responses:
• Correct reception: &&aa!\ckckCR
• Incorrect reception: &&aa?\ckckCR
Reading Weight, The Setpoint And The Peak (If Present) From The Pc:
The PC transmits: $aajckckCR
To read the points, set the
equal to 50000. $01p71CR
Data
Definition
xxxxxx
6 characters for the setpoint value (48 ? 57 ASCII)
y
A (set the value in the Setpoint 1)$01010000A40CR
y
B (set the value in the Setpoint 2)$01010000B42CR
y
C (set the value in the Setpoint 3)$01010000C43CR
Table 3-39. Setpoint Value Definitions (ASCII)
Data
Definitions
j
a to read setpoint 1$01a60CR
j
b to read setpoint 2$01b63CR
j
c to read setpoint 3$01c62CR
j
t to read gross weight$01t75CR
j
n to read net weight$01n6FCR
j
p to read the gross weight peak if the ASCII parameter is set as NOdU60;
if the ASCII parameter is set on NOd td the gross weight will be read.
Table 3-40. Weight, Setpoint, Peak Definitions (ASCII)