RoughDeck CS Rail Car Coil Scale
8
Visit our website
6. If conduit protection is necessary against mechanical or rodent damage to the load cell cables, use flexible conduit
and conduit adapter at the load cells.
Flexible conduit and conduit adapters are an optional item and not included with the standard setup.
7. Connect cables for load cells to the summing board in the junction box according to the guide shown in
and
the labels on the terminal strips of the junction box. To verify the wiring scheme, see the Certificate of Conformity (CC),
shipped with each load cell.
8. For performance, use positive and negative remote sense lines if the wiring running from the junction box to the
indicator is longer than 2
.
4.1 Trimming and Calibration
Refer to the JB4SS TuffSeal junction box manual (PN184803) for trimming details.
Refer to the indicator manual for connection and calibration details.
Load Cell Wire Color
Function
Red
+ EXC
Black
- EXC
Green
+ SIG
White
- SIG
Gray or Bare
Shield
Table 4-1. Load Cell Wiring
Note