Страница 1: ...ustin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and mea...

Страница 2: ...RL2200 Load Cell Mounting Kit Installation Guide 49596 Rev A...

Страница 3: ...Copyright Rice Lake Weighing Systems All rights reserved Printed in the United States of America Specifications subject to change without notice July 31 2013...

Страница 4: ...ank Mounts 3 Installing the RL2200 4 3 Load Cell Wiring 6 4 Junction Box Connections Adjustments Calibration 7 5 Troubleshooting 7 6 Maintenance and Replacement Parts 8 7 RL2200 Limited Warranty 9 Ric...

Страница 5: ...ii RL2200 Load Cell Mounting Kit Installation...

Страница 6: ...h no need for check or stay rods making this mount a good choice for areas with frequent seismic activity The rocker pin design eases load cell installation and replace ment without the need to raise...

Страница 7: ...ll or work on this equipment unless you have read and understand the instructions and warnings in this manual DO NOT use for purposes other than weight measurement DO NOT use any load bearing componen...

Страница 8: ...installation 4 Level 0 5 Flexible Piping J Box It is crucial that all piping or conduit be horizontal and flexi ble If flexible piping is not used make sure distance from vessel to the first pipe sup...

Страница 9: ...ed Does the supporting structure have the necessary strength to prevent excessive deflection when the system is fully loaded Is there attached equipment such as skirting venting or piping which is lik...

Страница 10: ...damage a load cell if dropped only a fraction of an inch 9 With the top plate positioned approximately level mark holes for attaching the top plate to the vessel s mounting surface Drill holes and at...

Страница 11: ...nction box Attach load cell cable to the dead structure not the vessel 3 If conduit protection is necessary against mechanical or rodent damage to the load cell cables use flexible conduit and conduit...

Страница 12: ...el or plumb moisture problem mechanical binding Drifting readout Moisture in junction box cables or load cell mechanical binding 1 Check load cell mount for debris restricting load cell movement or de...

Страница 13: ...4949 14949 45696 45696 RL2200 Stainless Steel Mounts No Description Replacement Part Numbers A B C D 1 Top Plate 45563 45563 45548 45548 2 Shoulder Screw 45568 45568 45552 45552 3 Load Cell Bolts 4557...

Страница 14: ...the sole judge of all alleged non conformities Such equipment has not been modified altered or changed by any person other than RLWS or its duly authorized repair agents RLWS will have a reasonable t...

Страница 15: ...10 RL2200 Load Cell Mounting Kit Installation...

Страница 16: ......

Страница 17: ...Rice Lake Weighing Systems July 31 2013 49596 Rev A...