Rice Lake MSI-4260 IS Скачать руководство пользователя страница 9

Installation

© 

Rice Lake Weighing Systems

 

 All Rights Reserved

5

2.0

Installation

The MSI-4260 IS features a heavy duty, cast aluminum enclosure. It installs easily by hanging it on a crane using properly sized 

shackles.

Refer to the Crane Scale Safety and Periodic Maintenance Manual (PN 153105) for safe loading and rigging 

guidelines when installing the model MSI-4260 IS.

Regular maintenance inspections of the lifting system should be performed to ensure safety. Pay particular 

attention for signs of stress on any element in the load train.

Use the appropriate interface hardware for the capacity of the scale. 

• If the interface hardware does not fit properly, Rice Lake Weighing Systems can supply the MSI-4260 IS with oversize 

lifting eyes or shackle interfaces. 

• If the crane hook is too large to fit in the lifting eye with single point interface, then install the scale using adaptive rigging.

• If multiple attachments are needed, use a shackle or ring to attach the multiple lines to keep a single point attachment to 

the scale. 

Using an oversize shackle or hook to interface with the MSI-4260 IS can cause off center loading and stress 

points that will reduce the life of the lifting eye or hook.

Single point attachments are necessary to ensure the safety and accuracy of the scale system.

2.1 Unpacking

When unpacking the MSI-4260 IS, ensure that all assembly parts are accounted for. Check the MSI-4260 IS for any visible 

damage. If any parts were damaged in shipment, notify Rice Lake Weighing Systems and the shipper immediately. 

If the MSI-4260 IS must be returned, it must be properly packed with sufficient packing materials. Whenever possible, use the 

original carton when shipping the unit back.

2.2 Battery Pack

The MSI-4260 IS is powered by a 12 V Sealed Lead Acid (SLA) rechargeable battery. 

This battery will operate for up to 80 hours (depending on LED brightness setting) before requiring recharging.

Charging time for a completely discharged battery is up to 12 hours. A spare battery pack is recommended to keep the 

MSI-4260 IS in continuous operation due to an extended battery charge time.

Only an Intrinsically Safe Battery (PN 167777) can be used with the MSI-4260 IS. This battery is incompatible with 

non-Intrinsically Safe MSI products. Refer to the Conditions of Use in Hazardous Locations (PN 184530) for 

intrinsic safety information on the battery.
To obtain maximum service life from the batteries they should be stored between -4°F and 122°F (-20°C and 

+50°C). Stored batteries should be recharged every three months. The battery is fully charged when the status 

indicator on the battery charger is flashing. 

2.2.1 Battery Life

The battery life of the

 

MSI-4260 IS depends on a number of factors: 

• The brightness of the LED display and number of segments lit

• The age of the battery

• The condition of the SLA battery

In order to conserve battery life, the MSI-4260 IS includes the following features.

• Automatic Power Off Mode — Senses no activity after the set amount of minutes and turns the scale off

• Automatic Sleep Mode — Dims the display after a set amount of minutes of no scale activity

The

 

MSI-4260 IS

 

automatically turns off when the SLA battery drops to approximately 10.5V. Recharge the battery when this 

happens; SLA batteries benefit from frequent recharging and can be recharged when it still has available life. 

Due to the maintenance discharge imposed on the battery by the MSI-4260 IS electronics, do not store the MSI-4260 IS with 

the battery inside. Remove the battery if it will not be used for more than two weeks.

Leaving a discharged battery in the scale, which has a maintenance battery drain, can result in a deep 

discharged battery which will shorten its service life.

*If the scale is in continuous use, a fully charged spare battery is recommended. Replace the drained battery as close as possible to the low 

battery warning.

** SLA batteries that have not been deep discharged should withstand 500 to 1500 charging cycles.

** The low battery warning annunciator indicates about two to four hours of additional use before the MSI-4260 IS turns itself off.

** If the MSI-4260 IS is not going to used again soon, remove the SLA battery to prevent deep discharge while the unit is in storage.

WARNING

IMPORTANT

WARNING

IMPORTANT

IMPORTANT

Note

Содержание MSI-4260 IS

Страница 1: ...MSI 4260 IS Port A Weigh Intrinsically Safe Crane Scale Technical Manual PN 173845 Rev C July 15 2021...

Страница 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Страница 3: ...ion of Menus 8 3 2 Power 8 3 3 Zero 8 3 4 Tare 9 4 0 Setup 10 4 1 Setup Menu 10 4 1 1 Set Function Key 11 4 1 2 Test 11 4 1 3 Total 11 4 1 4 View Total 12 4 1 5 Net Gross 12 4 1 6 Peak Hold 12 4 1 7 U...

Страница 4: ...binars 5 6 Calibration Setup Menu 22 5 6 1 Standard Menu 22 5 7 Auto Zero Maintenance 23 6 0 Maintenance 24 6 1 Troubleshooting 24 6 2 Service Counters 25 6 2 1 Access the Service Counters 25 6 3 MSI...

Страница 5: ...ld class features and accuracy Five large 1 2 30 5 mm LED digits for clear weight readings from a distance The display is always tilted down for ease of viewing from below Easy to maintain Full digita...

Страница 6: ...eep a safe distance Do not use for purposes other than weight taking or dynamic load monitoring Do not use any load bearing component that is worn beyond 5 of the original dimension Do not use the sca...

Страница 7: ...Off Zero Key Used to zero out residual weight on the scale Tare Key Removes the weight of containers trucks or carriers and places the scale in the Net weight mode User Key Programmable to user selec...

Страница 8: ...arnings Blue LED Setpoint 1 Green LED Setpoint 2 Red LED Setpoint 3 TTL Total Blue LED indicates the total weight displays for five seconds or less NET Net Indicates the scale is in Net mode Tare weig...

Страница 9: ...I 4260 IS in continuous operation due to an extended battery charge time Only an Intrinsically Safe Battery PN 167777 can be used with the MSI 4260 IS This battery is incompatible with non Intrinsical...

Страница 10: ...e Use the following steps to charge a battery 1 Remove the battery from the MSI 4260 IS Figure 2 2 on page 7 2 In a safe environment plug the polarized connector into the jacks on the battery 3 Connec...

Страница 11: ...Sealed Lead Acid battery can be a dangerous falling hazard When opening the battery hatch be sure to hold the battery to prevent it from falling These batteries contain lead and should be recycled wh...

Страница 12: ...mber displays The MSI 4260 IS is ready for use 3 3 Zero The Zero key sets the zero reading of the scale Press to take out small deviations in zero when the scale is unloaded See Section 3 4 on page 9...

Страница 13: ...ay the net weight press The weight reading must be stable within the motion window for the tare function to work The scale digits display 0 or 0 0 or 0 00 etc and the weight mode changes to NET The ba...

Страница 14: ...HB44 modes Units See Section 4 1 7 on page 12 Function not available or non functional in OIML R76 1Unit modes High Resolution x10 display resolution All annunciators blink For testing and maintenanc...

Страница 15: ...s are performed and if any test fails an error code displays See Section 6 1 on page 24 for information on the troubleshooting guide To stop the automatic test procedure press the F key again within t...

Страница 16: ...er rate than typical scales Peak hold is cleared and re enabled with the F key Peak hold is not available on NTEP or OIML Legal for Trade certified scales 4 1 7 Units Units can be changed in two ways...

Страница 17: ...time to cancel the procedure 4 3 Sleep The Sleep parameter reduces power consumption by automatically turning off the display during periods of inactivity While in the sleep mode the green acknowledge...

Страница 18: ...setting The display brightness will reduce as ambient light reduces There are four fixed brightness settings LO 1 LO 2 HI 1 and HI 2 Lower brightness settings increase battery life 1 Press and hold a...

Страница 19: ...sired value displays To enter a decimal point press while the digit is blinking To correct a digit press to step back 12 Press The value stops blinking and the next Setup menu item displays 13 Repeat...

Страница 20: ...the number of samples displays for two seconds Weight is less than 1 of capacity The USER key functions as View Total only and functions as View Total until the 1 threshold is exceeded to allow the ne...

Страница 21: ...lect The next item in the Setup menu displays 6 Press to save and exit to weighing mode or press to continue to another Setup menu item 4 8 Units 1 Press and hold and then displays If the unit is on p...

Страница 22: ...d Calibration Used for maintenance and routine calibration Initial Calibration Used to set up both the capacity and resolution d of the scale It differs from standard calibration only in the initial s...

Страница 23: ...ss to save that digit selection Press to save the next digit selection Press to save the next digit selection displays 7 Press to save the weight entry If the cal value is within limits is briefly dis...

Страница 24: ...the filtering Never program the resolution higher than needed If the MSI 4260 IS display is never stable it is recommended that the resolution is reduced and or filtering increased Due to Legal for Tr...

Страница 25: ...libration will erase the additional span points as C Cal is only a two point calibration zero and span at 10 of capacity Use the following steps to perform a C Cal calibration 1 Remove the hex seal sc...

Страница 26: ...o units switching filters and peak hold Handbook 44 Hb 44 Sets the scale to enable only approved features per the NTEP HB 44 rules and regulations Access is denied to Peak Hold and the zero range may...

Страница 27: ...AZM capture window The AZM capture window usually 1 d and capture time usually eight seconds can be adjusted by MSI to meet custom requirements The settings of AZM are dictated in Legal for Trade sta...

Страница 28: ...es between and Weight exceeds capacity Reduce weight immediately Faulty load cell or wiring Check load cell and load cell wiring The display toggles between and Weight in below the zero range If the s...

Страница 29: ...of overloads and also when there is a chance of fatigue failure The power up routine will be interrupted when the lift counter exceeds 16383 lifts or the overload counter exceeds 1023 overloads If th...

Страница 30: ...1 105lb 10 000 kg 2 kg 724 mm 101 6 mm 159 mm 66 5 mm 61 2 mm swivel eyenut 47 kg 30 000 lb 10 lb 30 0 in 4 00 in 6 25 in 3 00 in 3 19 in 22 ton alloy CR 11 125lb 15 000 kg 5 kg 762 mm 101 6 mm 159 mm...

Страница 31: ...LED with programmable brightness control Displayable Units Pounds or kilograms selectable Annunciators COZ Net Gross Total Peak Low Battery lb kg Motion Setpoints Power 12 V rechargeable battery 115...

Страница 32: ...MSI 4260 IS Port A Weigh 28 Visit our website www RiceLake com...

Страница 33: ......

Страница 34: ...anada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems is an ISO 9001 registered company Rice Lake Weighing Systems Specifications subject to change wi...

Отзывы: