Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
23
3.7.3 Display Message Command Format (Matrix Display)
3m8 and 3m12 remotes.
|<AA><DM>|<Timeout>|<Flash>|<Slide On>|<Scroll>|<Scroll Count>|<Data>!
where:
| = Pipe character (0x7C)
AA = Two byte address, ASCII digits
DM = Two byte command, ASCII characters
| = Pipe character (0x7C)
<Display Timeout> = Milliseconds to display the message (N/A for scroll). 32,767 (32 seconds) is the maximum timeout.
Values above the number indicates an indefinite display.
| = Pipe character (0x7C)
<Flash> = “Y” or “N”
| = Pipe character (0x7C)
<Slide On> = “Y” or “N”
| = Pipe character (0x7C)
<Scroll> = “Y” or “N”
| = Pipe character (0x7C)
<Scroll Count> = Number of times to scroll the message or “A” for annunciator msg cmd (learn enable = OFF)
| = Pipe character (0x7C)
<Data> = Text to display
! = Exclamation point character (0 x 21)
Examples: Scroll the message “Rice Lake Weighing Systems” twice:
|00DM|0|N|N|Y|2|Rice Lake Weighing Systems!
Slide on and flash the message “DRIVE AHEAD” for 5 seconds:
|00DM|5000|Y|Y|N|0|DRIVE AHEAD!
Command
Description
DM
<Data> is the six character message to display; If less than six characters, send spaces to
make it six characters; Some data may not be overwritten
Example: |00DMSTOP !
GT
Get time and date; Information gathered is sent back to the indicator, allowing both the remote
display and indicator to match; This is not displayed on the remote display
Example: |00GT!
ST
Set time and date
Example: |ST08:00:00 2003-01-31!
NOTE: Two spaces are required between time and date entries.
DI
Get digital input state
DO
Get digital output state
GR
Get relay state; Relay 0-3, 0=Off=LL, state 1=LH, state 2=HL, state 3=On=HH
SR
Set relay state (output relays only); Relay 0-1, state 1=On and 0=Off
GB
Get the number of 5 x 7 Max6953 boards (0 = 7-seg, 2, 3 = 5 x 7)
GV
Get the version number
DC
Dump configuration parameters (for testing purposes only)
TP
Temperature adjustment; Allows ±5% degree adjustment
Time and date is sent from the remote display depending on the current remote display time and date format;
Time and date are sent to the remote display in ISO format:
USA Format: HH:MM:SS AM/PM MMM/DD/YYYY
ISO Format: HH:MM:SS YYYY-MM-DD
If the real time clock is disabled in the remote display, an error message is sent back
Table 3-11. Display Message Command Format