Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
17
Serial Menu
Port 0 Parameter
Choices
Description
Level 3 Submenus
7-Segment Display
Parameters
8-Character Display
Parameters
12-Character Display
Parameters
BAUD
BAUD
BAUD
1200
Baud rate; Selects the transmission speed for Port 0
2400
4800
9600
19200
PARITY
PARITY
PARITY
ODD
Selects the parity of data of Port 0
EVEN
NONE
DATA
DATABITS
DATA BITS
7
Selects the number of data bits of Port 0
8
7-Segment Display
Parameters
8-Character Display
Parameters
12-Character Display
Parameters
STOP
STOPBITS
STOP BITS
1
Selects the number of stop bits of Port 0
2
HOLD WT
HOLD WT
HOLD WEIGHT
ON
Select On to enable this feature to keep the last weight displayed
if communication is lost or if using demand updated weight and prevents
remote display from going into an error condition
OFF
LOCK
LOCK
LOCK
ON
Select On to make sure the current settings do not get changed
and to disable Auto-Learn; When off, the system enables the
Auto-Learn function
OFF
E CHAR
END CHAR
END CHAR
CR
When Auto-Learn is enabled, this feature looks at the last
character to determine the end of a packet
LR
FF
ETX
LW POS
L WT POS
LAST WT POS
5–50
Select a number between 5 and 50 to determine the last weight position;
If setting up Port 0 manually, the last weight position is zero indexed
Example: <STX>123456<CR> where <STX> is the start of the text
character, and <CR> is a carriage return character, the “6” is in the 6th
position, not the 7th.
LENGTH
LENGTH
LENGTH
5–75
Select a number between 5 and 75 to determine the length of the packet in
the string format; Formats such as Toledo 8142 end in CR<AA> where
<AA> is a 2-byte checksum, the checksum must not be counted when
calculating the format length
PRIM U
PRIM UNT
PRIM UNITS
A–Z
Select a primary display character from A-Z; If selected, annunciator is lit
SECD U
SECD UNT
SECD UNITS
A–Z
Select a secondary display character from A-Z; If selected, annunciator is
lit
GROS C
GROSS CH
GROSS CHAR
A–Z
Select a gross character from A-Z; If selected, annunciator is lit
NET C
NET CHAR
NET CHAR
A–Z
Select a net character from A-Z; If selected, annunciator is lit
MOTION
MOTION
MOTION
A–Z
Select a motion display character from A-Z; If selected, annunciator is lit
SP IND
SP IND
SPECIAL IND
0
Off (select when not using a special indicator)
NOTE: If using a Mettler Toledo indicator named something other
than a numeric model, Zero may need to be set. If using a Mettler
Toledo numbered model indicator, set to one.
1
Toledo 8142 format bit-mapped status data
2
Inclinometer custom program
3
Flex-Weigh DWM IV
4
Fairbanks 2500/and 9401 compatible units
5
AnD 4323
Table 3-5. Port 0 Serial Menu