Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
7
3.3 Manual Configuration Using W.rEPE
W.rEPE is a configurable mode that allows identification and location of data in the strain. The
W.rEPE
parameter is selected, it
allows for the manual configuration of parameters to parse string data. The manual configuration is defaulted to read the Rice
Lake continuous format.The Rice Lake continuous format is defined as:
Figure 3-3. STR-1 Rice Lake Stream Data Format
Figure 3-4. String Configuration Parameters
The following parameters must be set when working in
W
.
rEPE
:
*
Wei
.
Pos
*
Wei
.
Len
*
Adv
.
Ced
Parameter
Description
tErN
Terminator – Identifies the string terminator at the end of the string in ASCII code; Default value is 10 = LF
wEi.PoS
Weigh Position – Identifies the 1st character position of the weight in the string; 1st string character has index zero;
WEi.LEn
Weigh Length – Identifies number of characters of the weight data string; Default value is 08 (polarity and seven weight digits)
Str.LEn
String Length – Identifies the length of the string transmitted from the indicator; Enter a value from
0
–
39
; Default value is 13
dECi
Decimal –Enter a number of scale decimals from
0
-
5
for
FIXED
; Default value is
STREAM
unit
Unit –Identifies unit of measure; available units are
G
,
Lb
,
t
,
KG
; Default unit of measure is
Lb
but not available for incoming data
StAb
Stability – Identifies number of readings used to compare for stability; Default value is 3
StA.int
Stability Intensity – Identifies weight difference for the stability sample between reading to identify motion; Default value is 2
trShLd
Threshold – Identifies minimum and maximum capacity for display blanking
AdU.CEd
Advanced – See
for advanced settings information
req.Wei
Not applicable
rEM.KEy
Remember Key – Settings:
K.Zero
,
K.tare
,
K.ModE
,
K.Print
;
Allows for the command to be sent to the indicator when the relative function key is pressed;
Up to 12 characters can be defined for the string if the first character is ASCII 0 the remote key is disabled;
Function key defaults are:
• ZERO = KZERO<CR>
• TARE = KTARE<CR>
• MODE = KGROSSNET<CR>
• PRINT = KPRINT<CR>
Table 3-3. String Configuration Parameter Definitions
W.rEPE
tErn
Wei.PoS
WEi.LEn
Str.LEn
dECi
unit
StAb
StA.int
trShLd
AdU.CEd
rEq.Wei
rEM.key
Note
Содержание Laser-LT-100