background image

Installation

© Rice Lake Weighing Systems

 

 All Rights Reserved

5

Item No.

Part No.

Description

Qty.

1

192293

Frame, Top Assembly 12 x 18 HE-X

1

191534

Frame, Top Assembly 18 x 18 HE-X

191815

Frame, Top Assembly 18 x 24 HE-X

191781

Frame, Top Assembly 24 x 24 HE-X

2

192287

Frame, Bottom Bench Scale 12 x 18 SST 50 lb – 100lb HE-X

1

191522

Frame, Bottom Bench Scale 18 x 18 SST 50 lb – 300 lb HE-X

191649

Frame, Bottom Bench Scale 18 x 18 SST 500 lb – 1,000 lb HE-X

191814

Frame, Bottom Bench Scale 18 x 24 SST 50 lb – 300 lb HE-X

191872

Frame, Bottom Bench Scale 18 x 24 SST 500 lb – 1,000 lb HE-X

191770

Frame, Bottom Bench Scale 24 x 24 SST 50 lb – 300 lb HE-X

191807

Frame, Bottom Bench Scale 24 x 24 SST 500 lb – 1,000 lb HE-X

3

191519

Shim, 0.1196 x 2.07 x 2.90 RLPCBC Load Cell SST

2

4

191518

Nut Coupling 1/2-20 NF Hex SST

4

5

191885

Rubber Foot 1/2-200 UNF SST

4

6

87022

Load Cell, SPT RLPCBC-60 50 lb Scale

1

87023

Load Cell, SPT RLPCBC-60 100 lb Scale

87023

Load Cell, SPT RLPCBC-60 150 lb Scale

87024

Load Cell, SPT RLPCBC-60 200 lb Scale

87024

Load Cell, SPT RLPCBC-60 250 lb Scale

87024

Load Cell, SPT RLPCBC-60 300 lb Scale

87025

Load Cell, SPT RLPCBC-60 500 lb Scale

87026

Load Cell, SPT RLPCBC-60 1,000 lb Scale

7

15154

5/16 Lock Washer Set

8

8

49789

Cap Screw 5/16-18NC x 1.25 Hex Head SST

8

9

15409

Clamp, Cable Nylon

1

10

184359

Screw, 8-32 x 1/4 Hex Head 18-8 SST

1

11

15132

Washer, Lock No. 8 Type A Internal Tooth SST

2

12

189464

Screw, 8-32 x 3/8 Hex Head 18-8 SST

1

13

183530

Screw, Cap 1/2-20NF x 0.50 Hex Head SST

1

14

187195

Level, Spirit Bubble Bulls Eye with Flange Plastic 21 x 16.5 x 9.5 mm

1

15

14963

Screw, Cap 1/4-20NC x 3/4 Hex Head SST F593

2

16

15149

Washer Plain 1/4 SST

4

17

105555

Nut, Coupling 1/4-20 x 0.48 Long SST

4

18

186936

Cover, Top Bench Scale 12 x 18

1

19094

Cover, Top Bench Scale 18 x 18

19095

Cover, Top Bench Scale 18 x 24

19096

Cover, Top Bench Scale 24 x 24

19

151269

Screw, Cap 1/4-20 NC x 1-1/4 Hex Head 18-8 SST

4

20

14954

Screw, Cap 1/4-20NC x 3/8 SST

2

Table 2-2.  Parts List

Содержание BenchMark HE-X

Страница 1: ...BenchMark HE X Hostile Environment Extreme Bench Scales Technical Manual PN 198967 Rev B May 19 2020...

Страница 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Страница 3: ...alling 715 234 9171 and asking for the training department 1 0 Introduction 1 1 1 Safety 1 2 0 Installation 2 2 1 Unpacking 2 2 2 Leveling the Scale 2 2 3 Connecting the Load Cell Cable 2 2 4 Groundin...

Страница 4: ...BenchMark HE X ii Visit our website www RiceLake com Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com webinars...

Страница 5: ...ould result in damage to equipment or corruption to and loss of data General Safety Do not operate or work on this equipment unless this manual has been read and all instructions are understood Failur...

Страница 6: ...e scale top cover and locate the level bubble 3 Adjust the four corner feet on the scale base until the level bubble and all feet contact the support surface so the scale does not rock 4 Lock the jam...

Страница 7: ...ral weights are used distribute them evenly around the platform 3 Perform a calibration 4 Remove certified calibration weights and check the zero reading If necessary repeat the calibration process Se...

Страница 8: ...HE X 4 Visit our website www RiceLake com 2 7 Replacement Parts See the following information for replacement parts details Figure 2 2 Parts Illustration 18 14 1 17 19 8 7 20 15 16 11 10 12 9 13 8 16...

Страница 9: ...Load Cell SPT RLPCBC 60 100 lb Scale 87023 Load Cell SPT RLPCBC 60 150 lb Scale 87024 Load Cell SPT RLPCBC 60 200 lb Scale 87024 Load Cell SPT RLPCBC 60 250 lb Scale 87024 Load Cell SPT RLPCBC 60 300...

Страница 10: ...remains at zero Incorrect load cell cable connections Faulty indicator Service indicator Erratic weight displays on indicator Vibration near the scale Remove the source of the vibration or adjust digi...

Страница 11: ...457 mm x 133 mm 18 75 476 mm 18 75 476 mm 100 lb 50 kg 150 lb 75 kg 200 lb 100 kg 250 lb 125 kg 300 lb 150 kg 500 lb 250 kg 1000 lb 500 kg 50 lb 25 kg 18 x 24 x 5 25 457 mm x 610 mm x 133 mm 18 75 47...

Страница 12: ...a wrench 6 The load cell and cable can now be removed from scale 7 Thread cable of replacement load cell through the scale frame as the unit arrived 8 Position load cell on shim and screw in four low...

Страница 13: ...ion of such equipment by RLWS confirms that the nonconformity actually exists and was not caused by accident misuse neglect alteration improper installation improper repair or improper testing RLWS sh...

Страница 14: ...18 18 x 24 24 x 24 Rated Output 0 91 mV V Maximum Overload 150 200 capacity dependent Overload Protection Five point independently adjusted Cable Length 10 3 m 6 wire shielded Output Impedance 1000 no...

Страница 15: ......

Страница 16: ...anada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems is an ISO 9001 registered company Rice Lake Weighing Systems Specifications subject to change wi...

Отзывы: