Specifications

© Rice Lake Weighing Systems

 

 All Rights Reserved

13

6.0

Specifications

Power

120 VAC - 9 VDC - 60Hz / 230 VAC - 9 VDC - 50Hz

Battery Type

6 AA size Alkaline batteries 

Battery Use

25 hours continuous use

Automatic power-off can be configured

Data Communications

RS-232 with RJ-45 jack

USB Connection

Selectable baud rate, default - 9600

8 bits

No parity

1 stop bit

No handshaking

Environmental

Operating Temperature

50°F to 95°F (10°C to 35°C)

Storage Temperature

32°F to 122°F (0°C to 50°C)

Humidity

85% relative humidity

Capacity and Graduation

1000 lb x 0.2 lb (453 kg x 0.1 kg)

Dimensions

Platform Dimensions

48.5 in W x 29.5 in L x 3 in H

Certifications and Approvals

 E113986

Содержание 350-10 Series

Страница 1: ...350 10 Series Digital Wheelchair Scales Software Version 11525 Operation Manual Model 350 10 2 Model 350 10 3 Model 350 10 7 Model 350 10 8 PN 151640 Rev E August 17 2022...

Страница 2: ...respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserves the right to...

Страница 3: ...ing or obtained by calling 715 234 9171 and asking for the training department Revision History This section tracks and describes the current and previous manual revisions for awareness of major updat...

Страница 4: ...mbly 3 2 1 Unpacking 3 2 1 1 Repacking Scale 3 2 2 Setting up Scale 3 2 2 1 Insert Batteries 5 2 2 2 Power Connection 5 3 0 Operation 6 3 1 Key Descriptions 6 3 2 Weighing 7 3 3 Hold Release Function...

Страница 5: ...ring and recalibration All that is required is to open the packaging and unfold the scale Manuals resources and warranties are available from Rice Lake Weighing Systems website at www ricelake com hea...

Страница 6: ...sport the scale while someone is on the scale Do not allow minors children or inexperienced persons to operate this scale Do not use in the presence of flammable materials Do not use this product if a...

Страница 7: ...y packed with sufficient packing materials Whenever possible use the original carton and packing materials when shipping the scale back Damage caused by improper packaging is not covered by the warran...

Страница 8: ...floor Not having clearance around the scale base creates inaccurate weighments Figure 2 2 Clearance Between Scale Base and Floor 6 Apply light pressure to all corners of the scale base to ensure there...

Страница 9: ...e used for an extended period of time If the LO BAT indicator activates for accurate weighing replace the batteries or connect the scale to an AC power source as soon as possible 2 2 2 Power Connectio...

Страница 10: ...BMI Pressing the BMI key enables access to the BMI Body Mass Index mode defaults when scale is turned on The patient is gets on the scale weight stabilizes and press the BMI key The display then asks...

Страница 11: ...y the patient 1 Press to turn on the scale 0 0 appears on the display along with the ZERO annunciator 2 Place additional item s on the scale 3 Press until the display returns to 0 0 and NET annunciato...

Страница 12: ...to adjust the height value 5 Press 6 The BMI value and BMI annunciator are shown on the display Press to return to the Weighing mode and the BMI function will be turned off 3 6 2 KG Mode 1 Ensure that...

Страница 13: ...high E07 AD too low E10 Overload Scale has been overloaded Remove load from scale E4L BAT Battery low but still usable one bar left on indicator display E4U Battery low and unstable no bars left on in...

Страница 14: ...press and hold for at least three seconds or until the scale emits two quick beeps If the scale does not beep after five seconds release as the weight was either in motion or out of range If displayin...

Страница 15: ...the use of the USB driver Driver protections may need to be temporarily disabled on Windows 10 or later computers to allow for the installation of the USB driver 1 Connect the scale s indicator to a P...

Страница 16: ...ice personnel Go through the following steps for basic maintenance Check the overall appearance of the entire scale for any obvious signs of damage Inspect the condition of the AC power adapter cord f...

Страница 17: ...figured Data Communications RS 232 with RJ 45 jack USB Connection Selectable baud rate default 9600 8 bits No parity 1 stop bit No handshaking Environmental Operating Temperature 50 F to 95 F 10 C to...

Страница 18: ...350 10 Series Digital Wheelchair Scales 14 Visit our website www RiceLake com...

Страница 19: ......

Страница 20: ...54868 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems Specifications subject to change without notice www ricelake com PN...

Отзывы: