background image

Page 

12

 / 

26

 

 

III. SAFETY INSTRUCTIONS 
 

Before using this product, read and understand all safety instructions. 
Always follow the safety instructions to minimize risk of damage to property, and to minimize any risk of 
damages and injuries to persons and animals. 
 

3.1- Symbols 

 

 

Caution!  Risk  of  injury  and/or  damage  and/or  deterioration  of  product  in  case  of 
non-compliance to safety requirements 

 

Read the instructions manual.   
 

 

Keep persons (esp. children) and animals away from product and working area 

 

Disconnect  product  from  its  power  source  before  maintenance,  cleaning  or  any 
intervention on product; or when you do not use product. 
Disconnect  product  from  its  main  power  source,  if  product,  power  cable,  or  extension 
cord is damaged or cut during operation. 
Unplug product by pulling the plug. Do not pull the cable. 

 

Do not dispose of this product with household rubbish. 
Dispose of this product in the nearest recycle centre. 
Please contact  your local authority or local recycle centre for further information for its 
safe disposal. 

 

3.2- READ ALL THE INFORMATION BEFORE OPERATING THE PRODUCT. 

1. Keep work area clean

 

Cluttered areas and benches invite accidents and injuries.

 

2. Consider work area environment

 

Keep work area well lit (natural light or sufficient artificial lighting). 
Keep work area well ventilated. 
Do not use product where there is  risk to cause fire or explosion (in the presence of flammable liquids, 
solids or gas).

 

3. Guard against electric shock

 

Avoid body contact with earthed or grounded surfaces (e.g. pipes, radiators, ranges, refrigerators).

 

4. Keep children away

 

Do not let bystanders touch the product or its power cable or extension cord.   
All bystanders (esp. children) should be kept away from product and work area. 
Keep  the  product  away  from  children  or  from  their  environment.  Never  allow  children  to  operate  the 
appliance. Children should be supervised to ensure that they do not play with the appliance. 
5. Store idle products 
When not in use, product should be stored in a dry, high or locked up place, out of reach of children. 
6. Do not force the product 
It will do the job better and safer at the rate speed for which it is intended. 
Do not use the product for purposes other than those for which it is intended. The product will do a better 
and safer job if it is used only for the purposes it was designed for. 
7. Use the right product 
Do not force small products or attachments to do the job of a heavy duty product.   
8. Dress properly 
When installing, do not wear loose clothing or jewellery; they can be caught in moving parts.   
Wear protecting hair covering to contain long hair. 

Содержание 512616

Страница 1: ...tilisation EN GARDEN PUMPAND BOOSTER PUMP User and maintenance manual IT POMPA DI SUPERFICIE E POMPA SURJET CARENATA Manuale di istruzioni e di manutenzione R f Art Nr PRJETF130 512616 PRS20JETF130 51...

Страница 2: ...entretien des piscines Ces pompes ne sont pas destin es pomper de l eau potable I NOMENCLATURE 1 Port d aspiration 2 Couvercle filtre 3 Port de refoulement 4 Poign e 5 Interrupteur 6 C ble lectrique...

Страница 3: ...e l environnement de l aire de travail Garder l aire de travail bien clair e lumi re naturelle ou artificielle suffisante Garder l aire de travail bien ventil e Ne pas utiliser le produit s il y a ris...

Страница 4: ...ion de rallonge Lorsque le produit est utilis avec une rallonge n utiliser que des rallonges con ues et pr vues pour supporter le courant alimentant le produit 16 Rester vigilant Surveiller ce que vou...

Страница 5: ...ctement vers l appareil ou d autres composants lectriques Danger de mort par lectrocution 9 Placer la rallonge de telle mani re qu elle ne puisse entrer en contact avec un quelconque liquide 10 Ne pas...

Страница 6: ...stall de mani re tre prot g contre les d bordements et contre les chutes Des exigences l gales nationales ou locales suppl mentaires peuvent exister et doivent tre observ es Lorsque vous utilisez le p...

Страница 7: ...e haut Dans le cas de puits comportant du sable ou des gravillons mettre la cr pine 50cm du fond ou dans un seau au fond du puits Le tuyau d aspiration doit tre aussi court que possible car la capacit...

Страница 8: ...st con ue pour aspirer des eaux claires Elle doit tre install e dans un lieu sec a r l abri des intemp ries et de la chaleur La hauteur maximum d aspiration ne doit pas d passer 8 m tres Correctement...

Страница 9: ...et de refoulement est ferm peut endommager s rieusement la pompe En cas de panne de courant il est pr f rable de d brancher la fiche de prise de courant En cas d inutilisation prolong e de la pompe co...

Страница 10: ...t Apporter le produit une d chetterie ou un centre de collecte des d chets des quipements lectriques et lectroniques ou renseignez vous aupr s de votre commune Effectuer la mise au rebut du produit de...

Страница 11: ...ools This pump is not intended for pumping drinking water I PARTS LIST 1 Intake port 2 Filter cover 3 Output port 4 Handle 5 On Off switch 6 Power cord with plug 7 Air valve 8 Tank 9 Manometer 512616...

Страница 12: ...ent Keep work area well lit natural light or sufficient artificial lighting Keep work area well ventilated Do not use product where there is risk to cause fire or explosion in the presence of flammabl...

Страница 13: ...common sense Do not operate product when you are tired under the influence of alcohol prescription medicines or drugs 17 Check damaged parts Before further use or reuse of the product it should be car...

Страница 14: ...ith the conveying medium 11 Do not leave the device unsupervised Unplug the mains plug during periods of extended absence 12 As a general rule repairs are only to be carried out by an electrician If r...

Страница 15: ...ts due to improper installation This pump must be installed in accordance with local standards and by a qualified person we recommend you to contact an electrician The fixed pipeline that will connect...

Страница 16: ...ine are an indication that there may be a leakage 4 5 Connecting the discharge line not supplied The discharge hose not supplied must have a minimum diameter of 25 mm and must be rigid and kink resist...

Страница 17: ...industrial and or commercial applications eg in public parks sports fields Additional information for booster pump The booster optimizes the water supply by limiting repeated on off and especially al...

Страница 18: ...detergents or abrasive sponges or sharp or pointed objects 6 2 Breakdown Never attempt to dismantle the pump If necessary have it checked and repaired by an authorized centre consult your dealer 6 3...

Страница 19: ...pompa non prevista per il pompaggio dell acqua di consume I ELENCO COMPONENTI 1 Bocca di aspirazione 2 Copperchio con filtro e bocca di adescamento 3 Bocca di scarico 4 Maniglia 5 Interruttore 6 Cavo...

Страница 20: ...Il disordine nell area di lavoro aumenta il rischio di incidenti 2 Tenere conto dei fattori circostanti di influenza Accertarsi che l illuminazione sia buona luce del sole o illuminazione artificiale...

Страница 21: ...pportare la corrente che alimenta l attrezzo 16 Fare sempre attenzione Guardare quello che si fa Procedere con giudizio Non utilizzare l utensile se non si concentrati si stanchi o sotto l influenza d...

Страница 22: ...avviare la macchina se persone o animali sono in acqua o in contatto con i tubi 11 Non lasciare incustodito l apparecchio Scollegare l alimentazione durante i periodi di non utilizzo o durante una lun...

Страница 23: ...o collegato alla pompa deve includere un dispositivo di separazione avente contatti cui larghezza dell apertura almeno pari a 3 mm in tutti i poli Si consiglia di alimentare la pompa di un trasformato...

Страница 24: ...essione della pompa Se il liquido contaminato un filtro di aspirazione deve essere usato per proteggere la pompa da sabbia e sporcizia IMPORTANTE Il tubo di aspirazione deve essere dotato di valvola d...

Страница 25: ...ua per reti di distribuzione dell acqua non alimentate pompaggio di acqua da serbatoi e lavaggio a spruzzi La pompa non deve essere impiegata per usi non indicati nel presente manuale In particolare l...

Страница 26: ...ompa deve essere accuratamentc vuotata o messa in condbioni fuori gelo Risciacquate periodicamente la pompa con acqua chiara compreso il circuito di aspirazione Evitare il pompaggio di liquidi che con...

Отзывы: