![RIB STOPPER Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/rib/stopper/stopper_manual_1453099021.webp)
21
21
G
B
I
NSTALLATION
All measures are expressed in milimeters unless otherwise indicated.
PRELIMINARY CONTROLS
•
Control the stability and solidity of the zone where the columns are
going to be fixed.
•
Use an omnipolar interrupter with contact distance of at least 3 mm.
•
The connection to the power supply must be seperated than the
connections to the security and commanding devices.
INSTALLATION OF THE COLUMN
(fig. 1, fig. 3, fig. 4)
1.
Screw in for 1,5 - 2,0 cm the 4 screws M10x70 in dotation to the
base.
2.
Place than the base on the previously prepared base of cement (fig.
3).
3. The upper part of the base should be clean and perfectly horizontal.
4.
Pass the plastic tubes of the cables through the central opening on the
base and check again the stability of the base.
5.
Unscrewing the 8 screws (10) take off the frontal (8) and the rear cover
(9) of the column (fig. 4).
6. Place now the column structure on the base.
7. Fix now the column to the base with the 4 washers (5) and 4 nuts (4).
8. Fix the frontal covers (8) of both columns with 4 screws (10).
9.
Now you can fix the chain to the apposite holes on both columns
respecting the level X in the middle of the chain barrier indicated at the
table (fig. 1).
M
AINTANENCE PLAN (EVERY 6 MONTHS)
1.
Cut the power supply off or disconnect the batteries if present. Clean
and grease the guide and the pignons internally.
2. See if there are weared parts and replace these if neccessary.
3. Grease the internal transmitting chain (fig. 5).
4. Check the fixation nuts (fig. 6).
5. Control the electrical connections.
6. Supply the power again.
7.
Check out the correct functioning of the obstacle recognition (encoder
system).
8. Check out the correct functioning of all and of the security commands.
6
5
4
Description:
1 - Column
2 - Gearmotor with encoder
3 - Control unit
4 - Autoblocking nut M10
5 - Washer 20x10
6 - Backing plate
7 - Screw M10x70
8 - Anterior cover
9 - Posterior cover
10 - Closing screw M5x10
M
ECHANICAL FUSE INSTALLATION
Screw TCEI M8X25 INOX
Spring D17 L13
Washer M12