background image

27

27

G

B

SYSTEM LAY-OUT

1 - PRINCE 24V operator

2 - Tuned aerial

3 - Flashing lamp

4 - Key selector

5 - Photoelectric cells (external)

T

ECHNICAL FEATURES

PRINCE 24V is a linear operator designed for swing gates long 

up to 2 m and weight up to 250 kg (Pic. 1).

PRINCE  24V  works  without  electric  limit  switches,  but  with 

mechanical stoppers.

N.B.:  It  is  advisable  to  fit  an  electrical  lock  to  ensure  an 

efficient gate locking.

TECHNICAL

DATA

Max. leaf length
Max. leaf weight
Max. travel
Average opening time
Operating speed
Power supply
Nominal Motor capacity
Max Motor capacity (blocked)
Nominal Power absorbed
Max Power absorbed (blocked)
Nominal Thrust force
Max Thrust force (blocked)
Normative cycles
Daily operations suggested
Service
Guaranteed consecutive cycles
Weight of the PRINCE 24V  
Noise
Operating Temperature
Protection grade

m. 

2

kg 

250

mm 

343**

s. 

14

m/s. 

0,0134

 

24Vdc

12

89

0,88

3,72

1000

1500

n° 

∞ - 14s/2s

n° 

60

80%

n° 

60/14s

kg 

5

db 

<70

°C 

-30 ÷ +55°C

IP 

44

PRINCE 24V

1

2

Measurements in mm

**  With incorporated mechanical stopper that cuts out during opening. 

If the mechanical stopper is used also during the closing (optional), 

the maximum stroke is reduced by 30 mm.

1

5

5

4

4

3

2

1

Содержание PRINCE 24V

Страница 1: ...31 a richiesta on request Peso max anta Poids maxi battant Max leaf weight Max Torgewicht Peso max hoja 250 kg 550 lbs Spinta Pouss e Thrust Schubkraft Empuje 100 kg 220 lbs Spinta max Pouss e maxi Ma...

Страница 2: ...e Operating speed Power supply Nominal Motor capacity Max Motor capacity blocked Nominal Power absorbed Max Power absorbed blocked Nominal Thrust force Max Thrust force blocked Normative cycles Daily...

Страница 3: ...ning in the gate frame and the side wall EMERGENCY MANUAL RELEASE This applies only if the unit is not equipped with back up batteries In case of a black out the gate can be pulled open after the oper...

Страница 4: ...1 2 90 L Min Max A max T sec COL ANT B C D E 110 0 100 100 765 90 13 5 S2 X A 20 100 100 765 90 13 5 S2 Y A 40 100 100 765 90 13 5 S3 X A 60 110 100 765 90 14 S3 Y A 80 140 110 765 115 17 S3 X B 100...

Страница 5: ...r A in the needed position by tightening the 8mA screw with a n 13 key To obtain the desired closing limit you must adjust the stopper B OPTIONAL in the needed position and tighten it as for stopper A...

Страница 6: ...ELLS STEP BY STEP COMMON COMMON 24Vdc 0 8A 15 for ACCESSORY SUPPLY 24Vdc 0 8A 15 for AUTOTEST SAFETY STRIPS BLINKER 24Vdc 20W LED R 2 2K 1 4W ELECTRIC LOCK PEDESTRIAN SAFETY STRIPS POWER SUPPLY 230Vac...

Страница 7: ...t clockwise increases the speed Adjustment is performed to determine the correct speed at the end of opening and closing according to the gate or when there is friction that might cause the system to...

Страница 8: ...button M1 stops 5 Press the PROG button M1 closes At the same time LED DL1 stops flashing indicating exit from the programming procedure Safety and other gate commands now operate normally inversions...

Страница 9: ...the sensor run after every full gate opening Closing the gate is therefore permitted only if the sensors have passed the functional test after each opening CAUTION MONITORING OF THE SENSOR INPUT CAN B...

Страница 10: ...STOP During functioning with personnel present with DIP 1 at ON check that during opening of M1 and M2 the green DL2 and DL4 LEDS switch on and that during closing of M1 and M2 the red DL3 and DL5 LE...

Страница 11: ...WIRELESS SYSTEM with connector 12 30V ac dc code ACG6094 with terminal block 12 30V ac dc code ACG6099 NOVA Wi Fi PHOTOCELLS WITHOUT WIRES code ACG8037 PAIR OF COLUMS NOVA code ACG8039 TOUCH Wi Fi ST...

Страница 12: ...posteriore Boccola vite senza fine Vite s fine Mot PRINCE EPIC MBT 24V Supporto motore 24V 230W Codice Denominazione Particolare CPL1163 CPL1164 CPL1165 CPL1167 CRS62042R CTC1116 CTC1253 CTC1269 CVA11...

Страница 13: ...ervice area it may be possible to book a local technician to look at your installation Wait times will vary dependent on local workloads The cost is a service fee which includes the first half hour an...

Отзывы: