13
13
G
B
DIP 4 ON => STRIP SENSOR OR PHOTOCELL 4 ACTIVATED
DIP 5 ON => STRIP SENSOR OR PHOTOCELL 5 ACTIVATED
DIP 6 ON => STRIP SENSOR OR PHOTOCELL 6 ACTIVATED
ATTENTION:
every time is executed a change of position of dip
switches, press PROG RX push-botton for 6 times to update the
system programming. At the end the dual-color leds must be turn off.
* OBLIGATORY connection for panels with a 120/230V ac blinker
output
** OBLIGATORY connection for panels with a 12/24V ac/dc blinker
output. ATTENTION: CHECK POLARITY
The connection is compulsory also in those cases where the blinker is
not installed in the system.
ATTENTION: Always connect the control panel blinker output to the
MASTER Wi-Fi card with one of the dedicated terminals, depending
on whether the blinker is 230V or connected to the wires of the J2
connector for 12/24V. If the connection is not made the door will not
work and the buzzer emits 4 sounds indicating that the connection is
missing.
PEDESTRIAN CONTROL (gray wire COM, green wire PED)
dedicated to
pedestrian radio-control.
EDGE INPUT (gray wire COM, yellow wire EDGE)
dedicated to the strip safety
device.
Attention:
any wire jumper present on the SAFETY STRIP terminals of control
panels must be removed.
PHOTOCELL INPUT (gray wire COM, black wire PHOT)
dedicated to
the photocell safety devices.
Attention:
any wire jumper present on the COM-PHOT terminals of RIB control
panels must be removed.
CONTROL BUTTON (gray wire COM, white wire N.O. BUTTON)
Disconnect every wired command from the control panel and connect it to this
white wire of MASTER Wi-Fi.
CONNECTION OF THE AUTO TEST INPUT (brown wire A/D+ TEST) for
compliance with standard EN13849-2:2008
-
If the panel used is equipped with auto test place jumper JP1 as indicated in
!
PED
green wire
COM
gray wire
EDGE
yellow wire
PHOT.N.C.
black wire
CONTROL BUTTON
white wire
A/D+ TEST
brown wire
*
!
**
12/24V ac/dc
6 5 4 3 2 1
+ -
10 9
6 5
2 1
+ -
1 Central
antenna connection 433,92 MHz
4+ 3-
Power feed
12/24V ac/dc
2 Antenna ground
6 5
Total opening
control contact
COM-OPEN/K
The Wi-Fi system is operating normally if
he handles all the radio controls (through
its 433 MHz radio module) and the wired
controls (through its white wire).
In case of using radio receivers and wired
controls (and therefore external to the Wi-Fi
system), for a correct functioning of the
system, these commands must be connected
through the white wire of the MASTER Wi-Fi.
120/230V ac
12/24V ac/dc
+
-
ATTENTION: The use of the product inside of metal containers can cause a system-malfunction. It is therefore recommended in these cases
to add the aerial code ACG5451 to apply to the metal casing for a perfect reception/transmission of the signals.
ATTENTION: USING MASTER Wi-Fi WITH OTHER BRANDS OF CONTROL PANELS SELECT ON THIS CONTROL PANELS THE PRE-
FLASHING FUNCTION (IF AVAILABLE).
It is strongly advisable to avoid using an automatic closing time delay, not longer than 1 minute.
The MASTER Wi-Fi card when inserted on RIB electronic control panels is protected against short circuits by a fuse connected to the secondary of the power supply.
When using a MASTER Wi-Fi card with control panels of other brands, please verify the presence of this protection.
In case it is not available, please connect a
fuse (T) of T 200 mA in series on the power supply.
- Turn off power to the automation control panel.
- Couple or connect the MASTER Wi-Fi card and perform the connections as in the following diagram.
NOTE:
The opening of the gate occurs 2 seconds after receiving a radio or push button command. That is done to allow the MASTER Wi-Fi card to verify the presence
and correct functioning of the memorized safety devices.
D
- CONNECTING THE MASTER Wi-Fi CARD