TECHNICAL FEATURES
Irreversible operating devices for sliding gates with a maximum weight of 1400
Kg/4900lbs.
The irreversibility of this operating device allows you to avoid using any electric lock for
an effective closing of the gate. The motor is protected by an heat probe, that temporary
interrupts the operating cycle in case of prolonged use.
1 - K operating device
2 - External photocells
3 - Rack of Module 4
4 - Key selector
5 - Radio antenna
6 - Blinker
7 - Travel limiting devices (cams)
8 - Internal Photocells
9 - Photocell posts
10 - Mechanical stops
Fig. 1
Fig. 3
Fig. 2
E
N
G
L
I
S
H
Pag. 19 di 36
SYSTEM LAY-OUT
CHECKING BEFORE THE INSTALLATION
!! THE GATE SHALL MOVE FRICTIONLESS !!
N.B.:
Gate features must be uniformed with the standards and laws in
force. The door/gate can be automated only if it is in a good condition and
its conditions comply with the EN 12604 norm.
- The door/gate leaf does not have to have a pedestrian opening. In the
opposite case it is necessary to take the appropriate steps, in
accordance with EN 12453 norm (for instance; by preventing the
operation of the motor when the pedestrian opening is opened, by
installing a safety microswitch connected with the control panel).
- Besides the electrical or mechanical limit switches available on the
operators, there must be, on both ends of the installation, a fixed
mechanical stopper which stop the gate in the unlikely event of ill
functioning of limit swithces on the operators. For this reason the fixed
mechanical stopper must be of an adeguate size to withstand the static
and kinetic forces generated by the gate (Fig.2 - point 12).
- Gate columns shall have anti-derailment guides on their top (Fig. 3), to
avoid the unintentional gate release.
N.B.:
Eliminate those mechanical stops of the kind described by figure 3.
No mechanical stop shall be on top of the gate, since mechanical stops
are not safe enough.
COMMAND TYPE
USE OF THE SHUTTER
Skilled persons
Skilled persons
Unrestricted use
(out of a public area*)
(public area)
with manned operation
A
B
not possible
with visible impulses (e.g. sensor)
E
E
E
with not visible impulses
(e.g. remote control device)
E
E
E
automatic
E
E
E
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated), like code ACG2013
B: Key selector with manned operation, like code ACG1010
E: Photocells, like code ACG8026 (To apply every 60÷70cm for all the height of the column of
the gate up to a maximum of 2,5m - EN 12445 point 7.3.2.1).
Parts to install meeting the EN 12453 standard
TECHNICAL
DATA
Max. leaf weight
EEC Power supply
Motor capacity
Power absorbed
Capacitor
No. normative cycles
Weight of operator
Protection
Noise
Working temperature
K1400 FAST
Operating speed
Thrust force
Grease
Rack
COMLUBE LHITGREASE EP/GR.2
Kg
8
db
<70
°C -10 ÷ +55°C
IP
54
Kg
1400
m/s
0,31
0,4
N
670
4
230V~ 50
60Hz
W
398
335
A
1,88
1,77
µ
F
16
n°
22-32s/2s
24-32s/2s
600
No. of daily operations suggested
Service
No. guaranteed consecutive cycles
70%
19/10m