RHINO MOTION CONTROLS
RMCS-1110
Hybrid Servo Driver with Modbus RTU communication
(Max. 80Vdc and 7A per phase)
Page 6
Hybrid AC Driver [RMCS-1110]
Switch Selection Table for Step Selection
Resolution
SW1
SW2
1/4
ON
ON
1/5
OFF
ON
1/2
ON
OFF
1x
OFF
OFF
1x = Encoder Counts Per Revolution (CPR)
Switch (3): Sets EEPROM permissions
SW3 ON – EEPROM Data Locked
SW3 OFF – EEPROM Data Unlocked
Switch (4): Sets Direction
SW4 ON – Forward Direction
SW4 OFF – Reverse Direction
RS-485 Command Port
A 2pin command port is available on the drive for debug and tuning routines. The communication is based
on Modbus RTU, the drive works as Modbus Slave and its register map is given in the Modbus Register
Table.
When connected it to a computer the drive parameters can be accessed by simple commands using any
Modbus Master Poll Software. An additional hardware to execute this process would be a USB to RS485
Converter. The baud rate of 115200 bps is default with 8 bit data, 1 stop bit and no parity.
The Modbus RTU Functions 03 (Read Multiple Registers), 05 (Write Single Coil) and 06 (Preset Single
Register) are used to control the drive.