List of banner warnings:
Banner warnings appear as scrolling text at the top of the user screens and
in the warning log of service display.
Code
Warning
Explanation
W100
PLC / HMI program version mismatch
Version numbers of PLC and HMI softwares must be
same. See first page in service mode.
W101
Parameters not OK. Check parameters
e.g. when replacing PLC the parameters must be set.
W102
Peridiocal service required. Contact local
service
The set service counter value has been achieved.
W103
Temperature calibration 50
0
C not done
Calibrated value at 50
0
C is missing.
W104
Temperature calibration 90
0
C not done
Calibrated value at 90
0
C is missing.
W105
Detergent calibration not done
Calibrated value is missing.
W300
SD memory card not in place or write
protected
Files from SD memory card can't be read or write
W301
SD memory card full
Less than 1 kbyte space on SD memory card
W302
Parameters not loaded from SD
Fault when reading a file from SD memory card.
W303
Cycle recipes not loaded from SD
Fault when reading a file from SD memory card.
W304
Calibration values not loaded from SD
Fault when reading a file from SD memory card.
W305
Cycle report save to SD failed
Fault when saving data to SD memory card.
W900
PLC not at run
Logic module in not in RUN mode
W901
PLC error
Fault in logic module.
W902
HMI error
Fault in display.
W903
Comm error
Communication between PLC and HMI does not work.
W904
PLC program missing
The application software is missing in logic module.