RHE26/27 Installation & Startup Guide – Doc. No. 8.2.1.06 – Ver. 1.40
8
Figure 2: RHE26/27
Wiring with RHM
Connection Type TM
3.2.1.2
RHM Electrical Connection Type TM (PTFE Cable)
Table 4: RHE26/27 Wiring Plan for RHM Connection Type TM
1
The shield of the cable is connected internally to the housing of the RHM. If there is a
risk of a significant potential difference between the housing of the RHM and the PE
terminal of the RHE, the shield should be connected to the RHE PE connection via a 1nF
capacitor. Alternatively, a separate cable can be run for potential equalization between
the RHM case and the RHE and the shield left both unconnected and isolated at the RHE
or terminated to the PE connection via a 1nF capacitor.
Upon power up, if the RHE indicates an error and the temperature measurement on the bottom
right of the display shows “ -.--°C/°F ” please check the temperature measurement configuration
setting in the RHE (section 4.5).
The correct temperature measurement configuration setting for an RHM with connection type
TM is “7”.
Cable
RHE2x Terminal
No.
Wire Color
Function
No.
Name
1
Brown
Drive Coil high
1
DrvH
2
Blue
Drive Coil low
2
DrvL
3
Red
Temp. Sensor Pipe
3
PtP
4
Pink
Temp. Sensors GND
4
PtG
5
Orange
Temp. Sensor Torsion
5
PtT
6
Yellow
Pick Up Coil A high
6
PkAH
7
Green
Pick Up Coil A low
7
PkAL
8
Grey
Pick Up Coil B low
8
PkBL
9
White
Pick Up Coil B high
9
PkBH
10
1
(yel/grn)
Shield
10
PE
Содержание RHE26
Страница 28: ...RHE26 27 Installation Startup Guide Doc No 8 2 1 06 Ver 1 40 28 7 Ordering Code 7 1 RHE26 7 2 RHE27 ...
Страница 40: ...Appendix B Technical Information Ver 1 00 40 B 2 2 RHE27 RHE27 E1 Transmitter Dimensions all dimensions in mm ...
Страница 41: ...Appendix B Technical Information Ver 1 00 41 RHE27 E2 Transmitter Dimensions all dimensions in mm ...
Страница 42: ...Appendix C CE Certificates Ver 1 00 42 Appendix C CE Certificates ...
Страница 43: ...Appendix C CE Certificates Ver 1 00 43 ...
Страница 44: ...Document No 8 2 1 06 Version 1 40 APR 2019 ...