Appendix B: Technical Information – Ver. 1.00
36
Appendix B
Technical Information
B.1
Technical Data
General Data
Housing:
IEC61554 Panel Mount Housing. Optional lockable front cover
Material:
Noryl
Enclosure Rating:
IP20; IP54 (front side only) with lockable front cover
Ambient Temperature:
-20°C to +60°C (-4°F to +140°F)
Humidity:
10 to 90% relative humidity, non-condensing
Altitude:
up to 3000m, higher maximum altitude upon request
Dimensions:
See drawing chapter B.2
Weight:
0.55kg / 1.2lb
Display:
High contrast backlit LCD. Screen changes color to indicate
warning or error
Operation:
3 x front panel operator buttons for all menu navigation and
settings
Power Supply:
AC: 100-240 VAC (48 to 62 Hz), 6W
DC: 12-24 VDC +/- 10%, 6W
Connection:
Pluggable cage clamp terminals
Interfaces:
Modbus RTU (RS485) and USB (standard)
HART over analog output (option)
Analog Outputs
Type:
4-20mA compliant to NAMUR NE-43
Signal type and quantity:
RHE26: 1 output, active, referenced to GND; RHE27: 0 to 2
outputs, active / passive
RHE27: 1 or 2, passive floating and active referenced to GND
Output value:
programmable
Digital Universal Outputs
Output signal:
Pulse, Frequency, Status
Type:
24V push-pull, according to IEC60946
Maximum current:
20mA (high state), 100mA (low state)
Frequency range:
0 ... 10 kHz
Quantity:
2
Содержание RHE26
Страница 28: ...RHE26 27 Installation Startup Guide Doc No 8 2 1 06 Ver 1 40 28 7 Ordering Code 7 1 RHE26 7 2 RHE27 ...
Страница 40: ...Appendix B Technical Information Ver 1 00 40 B 2 2 RHE27 RHE27 E1 Transmitter Dimensions all dimensions in mm ...
Страница 41: ...Appendix B Technical Information Ver 1 00 41 RHE27 E2 Transmitter Dimensions all dimensions in mm ...
Страница 42: ...Appendix C CE Certificates Ver 1 00 42 Appendix C CE Certificates ...
Страница 43: ...Appendix C CE Certificates Ver 1 00 43 ...
Страница 44: ...Document No 8 2 1 06 Version 1 40 APR 2019 ...