Equipment Selection
The installation of geothermal heat pump units and all
associated components, parts, and accessories which make
up the installation shall be in accordance with the regulations
of ALL authorities having jurisdiction and MUST conform to
all applicable codes. It is the responsibility of the installing
contractor to determine and comply with ALL applicable
codes and regulations.
General
Proper indoor coil selection is critical to system e
ffi
ciency.
Using an older-model coil can a
ff
ect e
ffi
ciency and may
not provide the customer with rated or advertised EER
and COP. Coil design and technology have dramatically
improved operating e
ffi
ciency and capacity in the past 20
years. Homeowners using an older coil are not reaping these
cost savings and comfort bene
fi
ts. NEVER MATCH AN R-22
INDOOR COIL WITH AN HFC-410A COMPRESSOR SECTION.
Table 1: Air Handler Matches for ARI Ratings
Compressor Section
025
036
048
062
Air Handler Model
RHPL-HM2421
RHPL-HM3621
RHPL-HM24
RHPL-HM6024
Refrigerant
HFC-10A
Metering Device
TXV (Non Bleed) required
Air Coil
Type
Rows - Fins/in.
Face Area (sq. ft.)
N Style
2 - 16 fpi
5.7
N Style
2 - 16 fpi
5.7
N Style
2 - 16 fpi
8.55
N Style
3 - 14 fpi
9.98
Cabinet Con
fi
guration
Up
fl
ow/Down
fl
ow/Horizontal (Multiposition)
ECM Settings
Comfort Control
System
Comfort Control
System
Comfort Control
System
Comfort Control
System
Fan Motor Type - HP
ECM - 1/3 HP
ECM - 1/2 HP
ECM - 3/4 HP
ECM - 3/4 HP
Newer indoor coils have a larger surface area, enhanced
fi
n
design, and grooved tubing. These features provide a larger
area for heat transfer, improving e
ffi
ciency and expanding
capacity. Typical older coils may only have one-third to one-
half the face area of these redesigned coils.
Indoor Coil Selection - RPVS and RPVE
Split system heat pumps are rated in the ARI directory with
a speci
fi
c indoor coil match. Matches with air handlers are
shown in Table 1. An ECM motor and TXV is required. Cap
tubes and
fi
xed ori
fi
ces are not acceptable.
Air Handler Match-ups