8) Room temperature control for wired remote controller sensor
Refer to Function 95, before performing this setting.
Depending on the installed environment, correction of the wired remote controller temperature
sensor may be required. Select the appropriate control setting according to the installed
environment.
To change this setting, set Function 42 to Both "01".
Ensure that the Thermo Sensor icon is displayed on the remote controller screen.
(
... Factory setting)
Function number
Setting value
Setting description
92
(For cooling)
93
(For heating)
00
No correction 0.0°F(0.0°C)
01
No correction 0.0°F (0.0°C)
02
-1°F (-0.5°C)
More Cooling
Less Heating
03
-2°F (-1.0°C)
04
-3°F (-1.5°C)
05
-4°F (-2.0°C)
06
-5°F (-2.5°C)
07
-6°F (-3.0°C)
08
-7°F (-3.5°C)
09
-8°F (-4.0°C)
10
+1°F (+0.5°C)
Less Cooling
More Heating
11
+2°F (+1.0°C)
12
+3°F (+1.5°C)
13
+4°F (+2.0°C)
14
+5°F (+2.5°C)
15
+6°F (+3.0°C)
16
+7°F (+3.5°C)
17
+8°F (+4.0°C)
9) Fixed operation mode switching
Sets the operation mode to heat pump, heating only, or cooling only.
(
... Factory setting)
Function number
Setting value
Setting description
94
00
Heat pump
01
Heating only
02
Cooling only
10) Heat Insulation condition (building insulation)
Heat insulation conditions differ according to the installed environment.
Standard insulation "00" allows system to rapidly respond to the cooling or heating load
changes. High insulation "01" is when the heat insulation structure of the building is high and
does not require system to rapidly respond to cooling or heating load changes.
When High insulation "01" is selected;
Overheating (overcooling) is prevented at the start-up.
All room temp. control settings (Function 30, 31, 92, 93) will reset to No correction [0.0°F
(0.0°C)].
(
... Factory setting)
Function number
Setting value
Setting description
95
00
Standard insulation
01
High insulation
NOTE:
When changing Function 95, perform this setting before other Room temp. control settings (Function 30, 31, 92,
93). If Funtion 95 is not set first, Room temperature control settings (Function 30, 31, 92, 93) will be reset and you
must re-do them again.
Содержание RIWH18ASJ
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE RIWH18ASJ RIWH24ASJ RIWH30AXJ RIWH36AXJ DTR_AS125E_01 2017 01 27...
Страница 36: ...2 OUTDOOR UNIT SINGLE TYPE ROSH18ASJ ROSH24ASJ ROSH30AXJ ROSH36AXJ DTR_AO226E_01 2017 01 27...
Страница 43: ...02 06 OUTDOOR UNIT ROSH18 36A OUTDOOR UNIT ROSH18 36A 4 WIRING DIAGRAMS MODEL ROSH18ASJ ROSH24ASJ...
Страница 44: ...02 07 OUTDOOR UNIT ROSH18 36A OUTDOOR UNIT ROSH18 36A MODEL ROSH30AXJ ROSH36AXJ...
Страница 52: ...02 15 OUTDOOR UNIT ROSH18 36A OUTDOOR UNIT ROSH18 36A 8 2 SOUND LEVEL CHECK POINT 39 3 8in 1m...