10. FUNCTION SETTING
10-1. INDOOR UNIT (Setting by remote controller)
•
The function settings of the control of the indoor unit can be changed by this procedure according
to the installation conditions. Incorrect settings can cause the indoor unit malfunction.
•
After the power is turned on, perform the “FUNCTION SETTING” according to the installation
conditions using the remote controller.
•
The settings may be selected between the following two: Function Number or Setting Value.
•
Settings will not be changed if invalid numbers or setting values are selected.
FUNCTION SETTING METHOD (for Wireless remote controller)
Entering the Function Setting Mode
• While pressing the FAN button and SET TEMP. (
) simultaneously, press the RESET button to enter the function
setting mode.
STEP 1
Setting the Remote controller Custom Code
Use the following steps to select the custom code of the remote controller. (Note that
the air conditioner cannot receive a signal code if the air conditioner has not been set
for the matching custom code.) The custom codes that are set through this process
are applicable only to the signals in the FUNCTION SETTING. For details on how to
set the custom codes through the normal process, refer to "REMOTE CONTROLLER
CUSTOM CODE".
1. Press the SET TEMP. ( ) ( ) button to change the custom code between
→
→ →
Match the code on the display to the air conditioner custom code. (initially
set to )
(If the custom code does not need to be selected, press the MODE button and
proceed to STEP 2.)
2. Press the TIMER MODE button and check that the indoor unit can receive signals
at the displayed custom code.
3. Press the MODE button to accept the custom code, and proceed to STEP 2.
The air conditioner custom code is set to A prior to shipment.
The remote controller resets to custom code A when the batteries in the remote controller are replaced. If you use a
custom code other than custom code A, reset the custom code after replacing the batteries.
If you do not know the air conditioner custom code setting, try each of the custom codes ( → → →
) until
you find the code which operates the air conditioner.
STEP 2
Selecting the Function Number and Setting Value
1. Press the SET TEMP. ( ) (
) buttons to select the function
number.
(Press the MODE button to switch between the left and right
digits.)
2. Press the FAN button to proceed to setting the value.
Press the FAN button again to return to the function number
selection.)
3. Press the SET TEMP. ( ) ( ) buttons to select the setting
value.
(Press the MODE button to switch between the left and right
digits.)
4. Press the TIMER MODE button, and START/STOP button,
in the order listed to confirm the settings.
5.
Press the RESET button to cancel the function setting
mode.
6.
After completing the FUNCTION SETTING, be sure to turn
off the power and turn it on again.
Function number
Setting value
CAUTION
After turning off the power, wait 30 seconds or more before turning on it again.
The FUNCTION SETTING doesn’t become effective if it doesn’t do so.
Содержание RIWH18ASJ
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE RIWH18ASJ RIWH24ASJ RIWH30AXJ RIWH36AXJ DTR_AS125E_01 2017 01 27...
Страница 36: ...2 OUTDOOR UNIT SINGLE TYPE ROSH18ASJ ROSH24ASJ ROSH30AXJ ROSH36AXJ DTR_AO226E_01 2017 01 27...
Страница 43: ...02 06 OUTDOOR UNIT ROSH18 36A OUTDOOR UNIT ROSH18 36A 4 WIRING DIAGRAMS MODEL ROSH18ASJ ROSH24ASJ...
Страница 44: ...02 07 OUTDOOR UNIT ROSH18 36A OUTDOOR UNIT ROSH18 36A MODEL ROSH30AXJ ROSH36AXJ...
Страница 52: ...02 15 OUTDOOR UNIT ROSH18 36A OUTDOOR UNIT ROSH18 36A 8 2 SOUND LEVEL CHECK POINT 39 3 8in 1m...