- (01 - 29) -
W
AL
L M
OU
NT
ED T
YP
E
RI
W
H
18
-3
6A
W
AL
L M
OU
NT
ED T
YP
E
RI
W
H
18
-3
6A
3) Auto restart
Enable or disable automatic restart after a power interruption.
(
... Factory setting)
Function number
Setting value
Setting description
40
00
Enable
01
Disable
* Auto restart is an emergency function such as for power outage etc.
Do not attempt to use this function in normal operation.
Be sure to operate the unit by remote controller or external device.
4) Room temperature sensor switching
(Only for Wired remote controller)
When using the Wired remote controller temperature sensor, change the setting to "Both" (01).
(
... Factory setting)
Function number
Setting value
Setting description
42
00
Indoor unit
01
Both
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller are active.
*Remote controller sensor must be turned on by using the remote controller.
5) Remote controller custom code
(Only for wireless remote controller)
The indoor unit custom code can be changed.
Select the appropriate custom code.
(
... Factory setting)
Function number
Setting value
Setting description
44
00
A
01
B
02
C
03
D
6) External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
(
... Factory setting)
Function number
Setting value
Setting description
46
00
Operation/Stop mode
01
(Setting prohibited)
02
Forced stop mode
7) Room temperature sensor switching (Aux.)
To use the temperature sensor on the wired remote controller only, change the setting to
"Wired remote controller" (01). This function will only work if the function setting 42 is set at
"Both" (01)
(
... Factory setting)
Function number
Setting value
Setting description
48
00
Both
01
Wired remote controller
Содержание RIWH18ASJ
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE RIWH18ASJ RIWH24ASJ RIWH30AXJ RIWH36AXJ DTR_AS125E_01 2017 01 27...
Страница 36: ...2 OUTDOOR UNIT SINGLE TYPE ROSH18ASJ ROSH24ASJ ROSH30AXJ ROSH36AXJ DTR_AO226E_01 2017 01 27...
Страница 43: ...02 06 OUTDOOR UNIT ROSH18 36A OUTDOOR UNIT ROSH18 36A 4 WIRING DIAGRAMS MODEL ROSH18ASJ ROSH24ASJ...
Страница 44: ...02 07 OUTDOOR UNIT ROSH18 36A OUTDOOR UNIT ROSH18 36A MODEL ROSH30AXJ ROSH36AXJ...
Страница 52: ...02 15 OUTDOOR UNIT ROSH18 36A OUTDOOR UNIT ROSH18 36A 8 2 SOUND LEVEL CHECK POINT 39 3 8in 1m...