background image

6

Rheem Manufacturing Company

BLOWER PERFORMANCE DATA—UPFLOW/HORIZONTAL MODELS

MODEL RGPR-

BLOWER SIZE

(D X W)

INCHES [mm]

ECM

MOTOR H.P.

[W]

BLOWER

SPEED

CFM [L/s] AIR DELIVERY

EXTERNAL STATIC PRESSURE

INCHES WATER COLUMN [kPa]

.1 [.025]–.8 [.2]

05

11 x 7

[279 x 178]

3/4

[559]

HIGH

MED-HI

MED
LOW

1200 [566]
1000 [472]

800 [378]
600 [283]

07A

11 x 7

[279 x 178]

1/2

[373]

HIGH

MED-HI

MED
LOW

1200 [566]
1000 [472]

800 [378]
600 [283]

10, 12

11 x 10

[279 x 254]

1

[746]

HIGH

MED-HI

MED
LOW

2000 [944]
1600 [755]
1400 [661]
1200 [566]

07B

11 x 10

[279 x 254]

3/4

[559]

HIGH

MED-HI

MED
LOW

1600 [755]
1400 [661]
1200 [566]
1000 [472]

Note:

See Coil Specification Sheet for coil data.

[

] Designates Metric Conversions

Содержание RGPR 05EBMKR

Страница 1: ...l Constant CFM Dip switch settings for selectable cooling airflow On demand dehumidification terminal for improved com fort in cooling mode Convertible from upflow to horizontal left or right Left or...

Страница 2: ...s optional accessories from a Rheem parts distributor For L P propane operation refer to Conversion Kit Index Form WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES STANDARD...

Страница 3: ...1 746 Motor Full Load Amps 9 6 7 7 12 8 12 8 Heating Speed CFM High Fire L s 850 401 1176 555 1600 753 1832 865 Heating Speed CFM Low Fire L s 625 295 980 462 1300 615 1420 670 Cooling CFM 5 kPa E S...

Страница 4: ...e with local codes Designates Metric Conversions UPFLOW DIMENSIONS UPFLOW DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL INCHES mm MODEL RGPR A B C D E REDUCED CLEARANCES IN mm 05 07A 171 2 445 1611...

Страница 5: ...S AND CLEARANCE TO COMBUSTIBLE MATERIAL INCHES mm WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR INSTALLATION ON ITS BACK WITH ACCESS DOORS FACING UPWARDS MODEL RGPR A B C D E REDUCED CLEARAN...

Страница 6: ...5 8 2 05 11 x 7 279 x 178 3 4 559 HIGH MED HI MED LOW 1200 566 1000 472 800 378 600 283 07A 11 x 7 279 x 178 1 2 373 HIGH MED HI MED LOW 1200 566 1000 472 800 378 600 283 10 12 11 x 10 279 x 254 1 746...

Страница 7: ...orifices If a burner orifice change is necessary they must be ordered through PROSTOCK See Installation instructions for more information Option 278 furnaces are shipped with 51 DMS orifices installed...

Страница 8: ...Provincial and Local codes regulations and practices RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road Fort Smith Arkansas 72908 In keeping with its policy of continuous progress and product im...

Отзывы: