![Rheem RGPR 05EBMKR Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/rheem/rgpr-05ebmkr/rgpr-05ebmkr_manual_1451444005.webp)
Rheem Manufacturing Company
5
NOTES:
➀
May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
➁
May be 0" [0 mm] with type B vent.
➂
May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with
local codes.
[
] Designates Metric Conversions
HORIZONTAL DIMENSIONS
HORIZONTAL DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]
WA R N I N G
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED FOR INSTALLATION
ON ITS BACK, WITH ACCESS DOORS
FACING UPWARDS.
MODEL
RGPR-
A
B
C
D
E
REDUCED CLEARANCES (IN.) [mm]
05, 07A
17
1
/
2
[445]
16
11
/
32
[415]
12
3
/
8
[314]
➀
15
[381]
0
3 [76]
➁
0
1 [25]
3 [76]
6 [152]
➂
LEFT
SIDE
RIGHT
SIDE
BACK
TOP
FRONT
VENT
SHIP. WGTS.
(LBS.) [Kg]
07B, 10
21
[533]
19
27
/
32
[504]
14
1
/
8
[359]
➀
18
1
/
2
[470]
0
0
0
1 [25]
3 [76]
6 [152]
➂
120 [54.4]
110 [49.9]
12
24
1
/
2
[622]
23
11
/
32
[593]
15
7
/
8
[403]
➀
22
[559]
0
0
0
1 [25]
3 [76]
6 [152]
➂
140 [63.5]
F
2
1
/
2
[64]
2
1
/
2
[64]
2
1
/
2
[64]
NOTE:
In horizontal configuration, return air cutout is not permitted.