Typical Cold Water Run Piping - Heating Apps
ALTERNATE SENSOR POSITION
12” MAX, OR MIN FEASIBLE
NOTES:
1. LOCATE UNIONS TO FACILITATE SERVICING OF PLUMBING SIDE.
2. PLUMB SWING CHECK VALVE IN GRAVITY-CLOSED POSITION.
3. PIPE ALL RELIEF VALVES TO DRAIN, OR AS LOCAL CODES REQUIRE.
4. SYSTEM FLOW MUST EXCEED HEATER FLOW AT ALL TIMES.
Typical Cold Water Run Piping - Pool Apps
SEE NOTE 4
NOTES:
1. LOCATE UNIONS TO FACILITATE SERVICING OF PLUMBING SIDE.
2. PLUMB SWING CHECK VALVE IN GRAVITY-CLOSED POSITION.
3. PIPE ALL RELIEF VALVES TO DRAIN, OR AS LOCAL CODES REQUIRE.
4. USE REDUCING TEES WHERE INDICATED.
5. SYSTEM FLOW MUST EXCEED HEATER FLOW AT ALL TIMES.