AIR FLOW PERFORMANCE - (-)801T SERIES (Downflow) MODELS

MODEL

MOTOR H.P. [W]

BLOWER SIZE 

IN [mm]

SPEED

TAP

CFM [L/s] AIR DELIVERY

EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa]

0.1 [.02]

0.2 [.05]

0.3 [.07]

0.5 [.12]

0.6 [.15]

0.8 [.19]

(-)801TA075317ZSA

1/2 [373]

11 x 7

[279 x 178]

Low

Med. Lo

Med

Med. Hi

High

916
993

1205

1367

1475

803
952

1158

1333

1444

669
910

1124

1300

1416

561
827

1056

1236

1354

504
793

1024

1203

1329

421
706
950

1140

1264

(-)801TA075521ZSA

1 [748]
11 x 10

[279 x 254]

Low

Med. Lo

Med

Med. Hi

High

1198
1411

1608

1918
2122

1105
1358

1564

1877
2083

1093
1317

1529

1840
2054

931

1227

1451

1767
1977

901

1196

1416

1706
1945

791

1093

1340

1636
1874

(-)801TA100521ZSA

1 [748]
11 x 10

[279 x 254]

Low

Med. Lo

Med

Med. Hi

High

1240
1405
1600

1903

2072

1120
1364
1561

1877

2028

1073
1317
1526

1833

2006

974

1232
1445

1766

1940

917

1181
1403

1711

1908

799

1083
1325

1631

1840

(-)801TA125524ZSA

1 [748]
11 x 10

[279 x 254]

Low

Med. Lo

Med

Med. Hi

High

1225
1302
1553

1902

2403

1073
1240
1503

1859

2369

988

1191
1455

1822

2332

864

1074
1370

1722

2246

795

1027
1313

1686

2190

697
932

1237

1602

2059

NOTE: Bold data is factory heating tap

[    ] Designates Metric Conversions

Air

Blower Performance Data

R801T (DF) Series

7

Blower Performance Data—Downflow Models

Содержание R801T DF Series

Страница 1: ...orrosion resistance and thermal fatigue reliability Low profile 34 cabinet ideal for space constrained installations Integrated Control board features dip switches for easy system set up QR code for quick access to product information from your smart phone or tablet Constant Torque electrically commutated motor Air Gas Furnaces R801T DF Series A F U E Annual Fuel Utilization Efficiency calculated ...

Страница 2: ...s R801T DF Series 2 TABLE OF CONTENTS Standard Optional Equipment 3 Model Features Physical Data Specifications 4 Model Number Identification 5 Dimensional Data 6 Blower Performance Data 7 Accessories 8 Limited Warranty 9 ...

Страница 3: ...sensor diagnostics on board twinning fused protection secondary 3rd speed option for continuous fan common heat cool terminal OPTIONAL EQUIPMENT NOTE Furnace is not listed for use with fuels other than natural or L P propane gas The complete terms of limited and other warranties are available at our sales office or through local installer All models can be converted by a qualified Rheem distributo...

Страница 4: ... 254 11 x 10 279 x 254 1hp 5spd X 13 746 1hp 5spd X 13 746 10 9 10 9 MED HIGH MED HIGH HIGH HIGH 2000 944 2000 944 0 5 0 12 0 5 0 12 30 60 17 33 35 65 19 4 36 1 190 87 7 185 85 0 120 54 140 63 80 0 80 0 AFUE Electronic Ignition Modules 80 0 80 0 NOTES All models are 115V 60HZ 1Ø Gas connection size for all models is 1 2 N P T In accordance with D O E test procedures See Conversion Kit Index Form f...

Страница 5: ...AFUE 1 Single Stage T Constant Torque Design Series A 1st Design Input BTU HR kW 075 75 000 22 100 100 000 29 125 125 000 37 3 Up to 3 Ton 4 21 2 to 4 Ton 5 31 2 to 5 Ton Cabinet Width 17 17 5 21 21 0 24 24 5 Z Down and Zero Clearance Downflow X Low NOx S Standard Revision Marketing A First Time Release Designates Metric Conversions ...

Страница 6: ...120 54 4 100 21 533 1927 32 504 137 8 352 201 8 511 0 0 0 1 25 3 76 6 152 120 54 4 125 241 2 622 2311 32 593 155 8 397 235 8 600 0 0 0 1 25 3 76 6 152 140 63 5 MODEL R801T DOWNFLOW SERIES B C D E Dimensional Data NOTES May require a 3 76 mm to 4 102 mm or 3 76 mm to 5 127 mm adapter May be 0 0 mm with type B vent May be 1 25 mm with type B vent Furnaces must be vented in accordance with the Nation...

Страница 7: ...2 1105 1358 1564 1877 2083 1093 1317 1529 1840 2054 931 1227 1451 1767 1977 901 1196 1416 1706 1945 791 1093 1340 1636 1874 801TA100521ZSA 1 748 11 x 10 279 x 254 Low Med Lo Med Med Hi High 1240 1405 1600 1903 2072 1120 1364 1561 1877 2028 1073 1317 1526 1833 2006 974 1232 1445 1766 1940 917 1181 1403 1711 1908 799 1083 1325 1631 1840 801TA125524ZSA 1 748 11 x 10 279 x 254 Low Med Lo Med Med Hi Hi...

Страница 8: ...DE INSTRUCTIONS Caution Always follow National Fuel Gas Code NFGC guidelines when converting for high altitudes High altitude option codes are not required for these models However the burner orifice size needs to be recalculated and verified at elevations above 2000 ft See Installation Instructions for more information NOTE For Canadian installations only an optional derate manifold gas pressure ...

Страница 9: ...within the applicable period stated in accordance with the terms of the limited warranty For complete details of the Limited and Conditional Warranties including applicable terms and conditions contact your local contractor or the Manufacturer for a copy of the product warranty certificate Heat Exchanger Twenty 20 Years Conditional Parts Registration Required Ten 10 Years ...

Страница 10: ...Air Notes R801T DF Series 10 ...

Страница 11: ...Air Notes R801T DF Series 11 ...

Страница 12: ...rt Smith Arkansas 72917 www rheem com In keeping with its policy of continuous progress and product improvement Rheem reserves the right to make changes without notice PRINTED IN U S A 7 14 QG FORM NO G11 549 Rheem Canada Ltd Ltée 125 Edgeware Road Unit 1 Brampton Ontario L6Y 0P5 ...

Отзывы: