Routine Preventative Maintenance

Properly maintained, your water heater 

will provide years of dependable 

trouble-free service.
It is suggested that a routine 

preventive maintenance program be 

established and followed by the user.
Most electrical appliances, even 

when new, make some sound when 

in operation. If the hissing or singing 

sound level increases excessively, 

Contact a qualified installer or 

plumbing contractor to inspect.

IMPORTANT: See "DANGER 

on left". 

At least once a year, lift 

and release the lever handle on the 

temperature pressure relief valve, 

located on the side of the water heater, 

to make certain the valve operates 

freely. Allow several gallons to flush 

through the discharge line to an open 

drain.

It is recommended to clean the 

filter on top of the heat pump 

when "Clean filter reminder" alert 

appears. Clean by washing with 

mild detergent and water. Dry and 

replace. Remove the filter by lifting 

up, then replace by lowering back 

into the filter slot on top of the unit. 

See Figure below.
Periodically check the condensate 

drain and condensate overflow 

to ensure they are open to permit 

draining of the condensate. 

A water heater’s tank can act as a 

setting basin for solids suspended 

in the water. It is therefore not 

uncommon for hard water deposits to 

accumulate in the bottom of the tank. It 

is suggested that a few quarts of water 

be drained from the water heater’s tank 

every month to clean the tank of these 

deposits.
Rapid closing of faucets or solenoid 

valves in automatic water using 

appliances can cause a banging noise 

heard in a water pipe. Strategically 

located risers in the water pipe system 

or water hammer arresting devices can 

be used to minimize the problem.

DANGER: Before 

manually operating the 

relief valve, make certain 

no one will be exposed to 

the danger of coming in 

contact with the hot water 

released by the valve. The 

water may be hot enough to 

create a scald hazard. The 

water should be released 

into a suitable drain to 

prevent injury or property 

damage. 

NOTICE: If the 

temperature and pressure 

relief valve on the 

water heater discharges 

periodically, this may be 

due to thermal expansion 

in a closed water system. 

Contact the water 

supplier or your plumbing 

contractor on how to 

correct this. DO NOT plug 

the relief valve outlet. 

Filter 

Handle

Vertical 

Flexible 

Filter

Care and cleaning of the water heater

Draining the Water Heater

CAUTION: Shut off power to the 

water heater before draining water.

DANGER: Before manually 

operating the relief valve, make 

certain no one will be exposed to the 

hot water released by the valve. The 

water drained from the tank may be 

hot enough to present a scald 

hazard and should be directed to a 

suitable drain to prevent injury or 

damage.

In order to drain the water heater, turn 

off the cold water supply. Open a hot 

water faucet or lift the handle on the 

relief valve to admit air to the tank.
Attach a garden hose to the drain 

valve on the water heater and direct 

the stream of water to a drain. Open 

the valve.

Содержание HB Duct Ready Series

Страница 1: ...u do not understand these instructions or any terms within it seek professional advice Any questions regarding the operation maintenance service or warranty of this water heater should be directed to...

Страница 2: ...great deal of time and money over the life of your water heater You ll find many answers to common problems in the Before You Call For Service section If you review our chart of Troubleshooting Tips f...

Страница 3: ...D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before sett...

Страница 4: ...ay call 916 445 8100 or ask a water heater dealer However applicable local codes shall govern installation For residential water heaters of a capacity greater than 52 gallons consult the local buildin...

Страница 5: ...elements or checking controls The water heater and water lines should be protected from freezing temperatures DO NOT install the water heater in outdoor unprotected areas Make certain the floor under...

Страница 6: ...ontrolling thermal expansion are also available Contact your installing contractor water supplier or plumbing inspector for additional information regarding this subject Water Supply Connections Refer...

Страница 7: ...al parts or persons and to eliminate potential water damage Piping used should be of a type approved for hot water distribution The discharge line must be no smaller than the outlet of the valve and m...

Страница 8: ...resulting in severe personal injury or death If the water heater has been subjected to fire flood or physical damage DO NOT operate the water heater again until it has been checked by a qualified ser...

Страница 9: ...ational Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements making an insulation blanket unnecessary The manufacturer s warranty does not cover any dam...

Страница 10: ...r is supplied with a built in water sensing circuit The water sensor rope is shipped in the warranty bag for field installation Remove water sensor rope from thebagandattachtotheconnector located near...

Страница 11: ...st is sufficiently away from structures to prevent condensation on surfaces Maximum heater performance is obtained by lowering the resistance to air flow regular filter maintenance is beneficial and p...

Страница 12: ...Bends Each Maximum Allowed 5 8 5 6 5 4 5 2 8 inch UL Certified Termination for ducting outside Each 5 5 5 5 Reduced diameter UL Certified Termination for ducting outside Each N A 10 15 20 8 inch Regi...

Страница 13: ...90 1 Kit should be purchased for this installation Ducting Example Flex Duct secured and sealed with Duct tie 2 places on Inlet 1 place on Outlet to secure Flex Duct to unit flange UL Certified termin...

Страница 14: ...er Air purged from water heater and piping Water connections tight and free of leaks Flexible water connections HVAC approved ducting Calculated length of duct no greater than maximum allowed UL Certi...

Страница 15: ...ing valves are recommended for reducing point of use water temperature by mixing hot and cold water in branch water lines It is recommended that a mixing valve complying with the Standard for Temperat...

Страница 16: ...tton Navigating the Home Screen To turn the water heating On press the Mode button once Water heater ships in the default Energy Saver mode with a temperature setting of 120 F Recommended temperature...

Страница 17: ...eriods This mode will result in maximum power consumption See Elec Heat Override Time in Settings Vacation This mode will allow duration setting between 1 and 28 days or set indefinitely with the Hold...

Страница 18: ...potential for HOT water SCALDS Energy Saver Mode Status Settings warm hot very hot Service Mode 120 Arrows to adjust temperature Energy Saver Mod Status Settings warm hot very hot Service Mode 120 set...

Страница 19: ...during service periods To Enabled Disabled the audible alarm press Enabled to highlight then press up down buttons to change to Enabled Disabled EcoNet Network Instance This number can be set between...

Страница 20: ...roduct Model Number Product Serial Number Software Version Number WH HPW4 H2 00 81 Water Heater Test Off alarms status sensors wifi status Water Heater Mode Off ECO Trip Electric Heat Control Off Comp...

Страница 21: ...ry month to clean the tank of these deposits Rapid closing of faucets or solenoid valves in automatic water using appliances can cause a banging noise heard in a water pipe Strategically located riser...

Страница 22: ...before placing it in operation NOTICE Refer to the Hydrogen Gas Caution in the Operating Instructions Anode Rod This water heater is equipped with an anode rod designed to prolong the life of the glas...

Страница 23: ...ff Confirm electric supply to water heater and see installation section of this manual The thermostat may be set too low See the Temperature regulation of the water heater section of this manual Leaki...

Страница 24: ...rm codes More information is available by selecting alarm and then pressing more info Current Alarms Alarm History A101 Suction Temperature Sensor Failure T300 Water Leak Sensor Not Installed A200 Hig...

Страница 25: ...unction Heater disabled A105 Evaporator Temp Sensor Failure Heatingsourcedefaultsto elementsduetoheatpump temperaturesensormalfunction A106 Discharge Temp Sensor Failure A107 Water Detected on Floor C...

Страница 26: ...unit 2 Refer to Use and Care Manual 3 Call your installer contractor 4 Call Tech Support at 1 800 995 0982 T300 Water Leak Sensor Not Installed Water Leak Sensor Not Installed 1 Install Water Leak Sen...

Страница 27: ...rating plate Part description as noted below and number of parts desired CAUTION For your safety DO NOT attempt repair of electrical wiring heating elements heat pump or electronic controls Refer rep...

Страница 28: ...ss panel s and insulation Rotate the crossbar up and down until it breaks away from the remainder of the cavity insert See illustration to the left Discard the crossbar It cannot and need not be repla...

Страница 29: ...E ECO EMERGENCY CUT OFF ET EVAPORATORTEMPERATURE EXV ELECTRONIC EXPANSIONVALVE FAN FAN GND NUT GROUND NUT ONTANK HPS HIGH PRESSURE SWITCH JCT BOX JUNCTION BOX LE LOWER ELEMENT LEAK LEAK SENSOR SOME MO...

Страница 30: ...act the Manufacturer s National Service Department at the following address 1241 Carwood Court Montgomery Alabama 36117 Phone 1 800 995 0982 When contacting the manufacturer the following information...

Отзывы: