Rheem Direct Vent Gas Tankless Water Heater Скачать руководство пользователя страница 7

1” (2.5 cm) min

1” (2.5 cm)

min

1” (2.5 cm)

min

Coaxial Vent Pipe
    & Air Intake

WARNING: Follow vent

manufacturer’s instruction
while installing vent. If
required, provide
additional clearances from
vent to combustibles per
vent manufacturer’s
instruction.

!

7

Installing the water heater :

This water heater must be installed in accordance with these instructions, local codes, utility company
requirements and/or in the absence of local codes, use the latest edition of the American National
Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association, 400
North Capitol Street Northwest, Washington, DC 20001 as ANSI standard Z223.1 or National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02269 as NFPA 54. In Canada, the latest edition of the CSA
B149.1 Natural Gas and Propane Installation, and the Canadian Electrical Code, CSA C22.1 Part 1, in the
absence of local codes.

Location of Water Heater

The water heater should not be located in
an area where leakage of the heat exchanger
or connections will result in damage to the
area adjacent to it or to lower floors of the
structure. 

When such areas cannot be avoided, it is
recommended that a suitable catch pan,
adequately drained, must be installed under
the water heater.

The pan must not restrict combustion 
air flow.

A gas fired water heater or any other appliance
should not be installed in a space where
liquids which give off flammable vapors are 
to be used or stored. Such liquids include
gasoline, LP gas (butane or propane), paint 
or adhesives and their thinners, solvents 
or removers.

Because of natural air movement in a room or
other enclosed space, flammable vapors can be
carried some distance from where their liquids
are being used or stored. The open flame of
the water heater’s main burner can ignite these
vapors causing an explosion or fire which may
result in severe burns, death or property
damage.

The water heater must be located so it is not
subject to physical damage, for example, by
moving vehicles, area flooding, etc. 

If the water heater is installed in a garage, it
should be installed so that the direct ignition
system and main burner are no less than 18
inches (45 cm) above the garage floor.

Raising the gas fired water heater will reduce
BUT NOT eliminate the possibility of lighting
the vapor of any flammable liquids which may
be improperly stored or accidentally spilled.

The water heater should be installed as
close as practical to the vent termination to
minimize vent length and the number of
elbows required for venting.

● 

The water heater 

should

be installed with

the proper venting materials and termination
suitable for 

Category III

venting.

A fire stop plate should be installed at every
penetration of a floor or ceiling if the vent is
not running in a fire rated shaft.

● 

Failure to install and properly vent the water
heater to the outdoors as outlined 
in the Venting Section of this manual 
can result in unsafe operation.

Long hot water lines should be insulated to
conserve water and energy. 

The water heater and water lines should 
be protected from exposure to freezing
temperatures.

Do not 

install the water heater in

bathrooms, bedrooms, any occupied rooms
normally kept closed, or in outdoor areas.

Do not

install the water heater in small,

poorly ventilated rooms, or in airtight 
rooms with air conditioning.

Do not

install water heater where subject 

to vibrations.

Do not

install the water heater in

Recreational Vehicles, Mobile Homes,
Boats and other Watercrafts.

Do not

install the water heater near vents

for heating or cooling.  A minimum of 4
feet (1.2 m) should be maintained.

Minimum clearance from combustible and
non-combustible construction is 1/2” (1.3
cm) sides, 0” rear (with support bracket);
12” (30 cm) from the bottom; 12” (30 cm)
from the front of the water heater; and 12”
(30 cm) from the top (24” [61 cm] from
front and top is recommended for servicing
purposes). 

Maintain a minimum clearance of 
1” (2.5 cm) around the coaxial vent pipe to
combustible or non-combustible
construction, unless otherwise specified by
vent manufacturer or installed in an
enclosed space. If the clearances stated on
the Instruction/Warning Label, located on
the front panel of the heater differ, install
the water heater according 
to the clearances stated on the label.

WARNING:

Combustible construction
refers to adjacent walls
and ceilings and should not
be confused with
combustible or flammable
products and materials.
Combustible and/or
flammable products and
materials should never be
stored in the vicinity of this
or any gas appliance.

!

min. 

1/2 " 

min. 

1/2 " 

min. 12" 

(24" (61 cm) minimum is
recommended for service)

min. 1"

min. 1"

(1.3 cm) 

(1.3 cm) 

(2.5 cm)

(2.5 cm)

(30 cm)

Minimum Clearance from

Combustible and 

Non-Combustible

Construction.

Top = 12" (30 cm)

Bottom = 12" 

Front = 12" (30 cm) Back = 0"*

Side = 1/2"

CoAxial Vent = 1"

*  (with support bracket)

Содержание Direct Vent Gas Tankless Water Heater

Страница 1: ...the proper installation and adjustment of the water heater and two to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This...

Страница 2: ...ce READ THIS MANUAL FOR YOUR RECORDS Write the model and serial numbers here You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date...

Страница 3: ...er flammable materials and liquids adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible mater...

Страница 4: ...ng allows operating temperatures between 100 F 38 C and 120 F 49 C Temperatures of up to 140 F 60 C can be achieved with the MAIN UMC 117 remote control and a dip switch adjustment Only qualified serv...

Страница 5: ...e or LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to...

Страница 6: ...ON READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage per...

Страница 7: ...of any flammable liquids which may be improperly stored or accidentally spilled The water heater should be installed as close as practical to the vent termination to minimize vent length and the numbe...

Страница 8: ...operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual also includes a parts list It is imperative that all persons who are expec...

Страница 9: ...eting the installation and putting the water heater into service DANGER Failure to install the appliance vent adapter and properly vent the water heater to the outdoors as outlined in the Venting sect...

Страница 10: ...and dispose of condensate from venting systems When a water heater is vented horizontally the vent pipe can have a DOWNWARD or UPWARD slope towards the termination If an UPWARD slope is used a condens...

Страница 11: ...let to any building or other appliance 6 inches 15 cm for appliances 10 000 Btuh 3 kW 12 inches 30 cm for appliances 10 000 Btuh 3kW and 100 000 Btuh 30kW 36 inches 91 cm for appliances 100 000 Btuh 3...

Страница 12: ...maintenance Do NOT extend exposed vent pipe of indoor water heaters outside of building Guard vent against accidental contact with people and pets Indoor Water Heater 12 WARNING Moisture in the flue...

Страница 13: ...Example A Typical Horizontal Termination w 1 4 per foot DOWNWARD Slope 13 Installing the water heater...

Страница 14: ...llow the vent manufacturer s recommended installation instructions provided with the vent purchased from the manufacturer Chase Requires 6 15 cm Clearance to Combustibles Firestop Firestop Roof Jack A...

Страница 15: ...or pressure relief valve To ensure proper operation of the water heater the following water pressure guidelines should be followed Operation of the water heater requires the minimum water pressure of...

Страница 16: ...e copper connections are recommended on the HOT and COLD water lines so that the water heater may disconnect easily for servicing if necessary Install a Check Valve between the water heater and the wa...

Страница 17: ...be installed in the discharge line Notice Local codes govern the installation of relief valves If local codes require that a temperature and pressure relief valve should be installed the manufacturer...

Страница 18: ...the action of LP gas Use compound sparingly on male threads only A sediment trap should be installed at the bottom of the gas line Do not use excessive force over 31 5 ft lbs 42 7 Nm in tightening the...

Страница 19: ...controls can connect to the water heater Therefore a maximum of three controls can connect to the water heater No other manufacturer s controls are suitable for use with this water heater DO NOT atte...

Страница 20: ...NING Field wiring connections and electrical grounding must comply with local codes or in the absence of local codes with the latest edition of the National Electrical Code ANSI NFPA 70 or in Canada C...

Страница 21: ...personal injury or death CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify correct operation after servicing BK 8 R...

Страница 22: ...22 Installing the water heater Typical Installation of Water Heater Venting Required...

Страница 23: ...y heat loss encountered with storage tank heaters This water heater does not store water making an insulation blanket unnecessary The manufacturer s warranty does not cover any damage or defect caused...

Страница 24: ...sufficient for the water heater Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Soap and water solution used to check all connections and fittings for...

Страница 25: ...and all other labels on the water heater as well as the warnings printed in this manual Failure to do so can result in unsafe operation of the water heater resulting in property damage personal injur...

Страница 26: ...alves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines Contact a licensed plumber or the local plumbing authority for further information Se...

Страница 27: ...otter water increases the risk of scald injury Always supervise young children or others who are incapacitated The water heater is equipped with a device that will shut off the gas supply to the burne...

Страница 28: ...nance and or cleaning ensure proper operation by turning on a hot water faucet Housekeeping Before performing Housekeeping tasks to this water heater turn the unit off and disconnect the power supply...

Страница 29: ...t It is recommended that qualified service personnel familiar with Category III venting inspect the venting system Check vent connection joint sections with a solution of soapy water to assure air tig...

Страница 30: ...freezing conditions even for a short period of time be sure to drain all water from the unit as instructed above Exposure to freezing conditions can occur from down draft of venting system or from in...

Страница 31: ...functions if applicable Check and replace if necessary Error code displayed on remote control See instructions for Error Code and if required contact a dealer for service Not enough water demand Incre...

Страница 32: ...r safety devices Refer repairs to qualified service personnel CAUTION Make certain power to water heater is OFF before removing protective cover FOR ANY REASON CAUTION Label all wires prior to disconn...

Страница 33: ...33...

Страница 34: ...splay of the Main Remote Control is on continuously Change the DIP Switch 4 setting back to the OFF position DO NOT alter any other DIP Switch The LED on the PCB will stop illuminating At the same tim...

Страница 35: ...35 Notes...

Страница 36: ...ll be located in the room that houses the appliance or equipment and shall a Be powered by the same electrical circuit as the appliance or equipment such that only one service switch services both the...

Отзывы: