Rheem Direct Vent Gas Tankless Water Heater Скачать руководство пользователя страница 11

D

V

V

E

FIXED
CLOS

ED

OPE

RAB

LE

OPE

RAB

LE

FIXE

D

CLOS

ED

v

v

B

L

F

C

B

v

v

v

X

B

B

B

A

J

B

I

H

X

v

M

K

v

G

A

The following information should be used for determining the proper location of the vent
terminal for direct vent tankless water heaters.

V

V

VE

EN

NT

T  T

TE

ER

RM

MIIN

NA

ALL

X A

AIIR

R  S

SU

UP

PP

PLLY

Y  IIN

NLLE

ET

T

A

AR

RE

EA

A  W

WH

HE

ER

RE

E  T

TE

ER

RM

MIIN

NA

ALL  IIS

S  N

NO

OT

T  P

PE

ER

RM

MIIT

TT

TE

ED

D

Horizontal Vent Terminal Location

1

In accordance with current CAN/CGA-B149 Installation Codes.

2

In accordance with current ANSI Z223.1/ NFPA 54 National Fuel Gas Code.

*

If clearances are not specified, then follow local installation codes and the requirement of the gas supplier.

** For condensing appliances: The vent for this appliance shall not terminate over public walkways, near soffit vents, crawl space vents,

or other areas where condensate or vapor could create a nuisance, hazard or cause property damage, or where condensate or vapor
could cause damage or could be detrimental to the operation of regulators, relief valves or other equipment.

H = Clearance to each side of center

line extended meter/regulator
assembly. above 

3 feet (91 cm) within a height 15 feet

(4.57 m) above the meter/regulator

assembly.

*

I =  Clearance to service regulator

coaxial vent outlet.

3 feet (91 cm)

*

J =  Clearance to nonmechanical air

supply inlet to the combustion air
inlet to any building or other
appliance.

6 inches (15 cm) for appliances <

10,000 Btuh (3 kW), 12 inches (30 cm)

for appliances > 10,000 Btuh (3kW)

and < 100,000 Btuh (30kW), 36 inches

(91 cm) for appliances > 100,000 Btuh

(30kW).

6 inches (15 cm) for appliances < 10,000

Btuh (3 kW), 9 inches (23 cm) for

appliances > 10,000 Btuh (3kW) and <

50,000 Btuh (15kW), 12 inches (30 cm)

for appliances > 50,000 Btuh (15kW).

K =  Clearance to mechanical air

supply inlet.

6 feet (1.83 m)

3 feet (91 cm) above if within 10 feet

(3 m) horizontally.

L =  Clearance above paved sidewalk

or paved driveway located on
public property.

Not Allowed

Not Allowed

M = Clearance under veranda, porch,

deck or balcony.

Not Allowed

Not Allowed

C

Caannaaddiiaann  IInnssttaallllaattiioonnss  

1

U

US

S  IInnssttaallllaattiioonnss  

2

A=  Clearance above grade, veranda,

porch, deck or balcony.

12 inches (30 cm) above anticipated 

snow level.

12 inches (30 cm) above anticipated 

snow level.

B=  Clearance to window or door that

may be opened.

6 inches (15 cm) for appliances < 10,000

Btuh (3 kW), 12 inches (30 cm) for

appliances > 10,000 Btuh (3kW) and <

100,000 Btuh (30kW), 36 inches (91 cm)

for appliances > 100,000 Btuh (30kW).

6 inches (15 cm) for appliances <

10,000 Btuh (3 kW), 9 inches (23 cm)

for appliances > 10,000 Btuh (3kW)

and < 50,000 Btuh (15kW), 12 inches

(30 cm) for appliances > 50,000 Btuh

(15kW).

C=  Clearance to permanently closed

window.

*

*

D=  Vertical Clearance to ventilated

soffit located above the terminal
within a horizontal distance of 2
feet (61 cm) from the center line
of the terminal.

*

*

E=  Clearance to unventilated soffit.

*

*

F=  Clearance to outside corner.

*

*

G=  Clearance to  corner.

*

*

11

Содержание Direct Vent Gas Tankless Water Heater

Страница 1: ...the proper installation and adjustment of the water heater and two to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This...

Страница 2: ...ce READ THIS MANUAL FOR YOUR RECORDS Write the model and serial numbers here You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date...

Страница 3: ...er flammable materials and liquids adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible mater...

Страница 4: ...ng allows operating temperatures between 100 F 38 C and 120 F 49 C Temperatures of up to 140 F 60 C can be achieved with the MAIN UMC 117 remote control and a dip switch adjustment Only qualified serv...

Страница 5: ...e or LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to...

Страница 6: ...ON READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage per...

Страница 7: ...of any flammable liquids which may be improperly stored or accidentally spilled The water heater should be installed as close as practical to the vent termination to minimize vent length and the numbe...

Страница 8: ...operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual also includes a parts list It is imperative that all persons who are expec...

Страница 9: ...eting the installation and putting the water heater into service DANGER Failure to install the appliance vent adapter and properly vent the water heater to the outdoors as outlined in the Venting sect...

Страница 10: ...and dispose of condensate from venting systems When a water heater is vented horizontally the vent pipe can have a DOWNWARD or UPWARD slope towards the termination If an UPWARD slope is used a condens...

Страница 11: ...let to any building or other appliance 6 inches 15 cm for appliances 10 000 Btuh 3 kW 12 inches 30 cm for appliances 10 000 Btuh 3kW and 100 000 Btuh 30kW 36 inches 91 cm for appliances 100 000 Btuh 3...

Страница 12: ...maintenance Do NOT extend exposed vent pipe of indoor water heaters outside of building Guard vent against accidental contact with people and pets Indoor Water Heater 12 WARNING Moisture in the flue...

Страница 13: ...Example A Typical Horizontal Termination w 1 4 per foot DOWNWARD Slope 13 Installing the water heater...

Страница 14: ...llow the vent manufacturer s recommended installation instructions provided with the vent purchased from the manufacturer Chase Requires 6 15 cm Clearance to Combustibles Firestop Firestop Roof Jack A...

Страница 15: ...or pressure relief valve To ensure proper operation of the water heater the following water pressure guidelines should be followed Operation of the water heater requires the minimum water pressure of...

Страница 16: ...e copper connections are recommended on the HOT and COLD water lines so that the water heater may disconnect easily for servicing if necessary Install a Check Valve between the water heater and the wa...

Страница 17: ...be installed in the discharge line Notice Local codes govern the installation of relief valves If local codes require that a temperature and pressure relief valve should be installed the manufacturer...

Страница 18: ...the action of LP gas Use compound sparingly on male threads only A sediment trap should be installed at the bottom of the gas line Do not use excessive force over 31 5 ft lbs 42 7 Nm in tightening the...

Страница 19: ...controls can connect to the water heater Therefore a maximum of three controls can connect to the water heater No other manufacturer s controls are suitable for use with this water heater DO NOT atte...

Страница 20: ...NING Field wiring connections and electrical grounding must comply with local codes or in the absence of local codes with the latest edition of the National Electrical Code ANSI NFPA 70 or in Canada C...

Страница 21: ...personal injury or death CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify correct operation after servicing BK 8 R...

Страница 22: ...22 Installing the water heater Typical Installation of Water Heater Venting Required...

Страница 23: ...y heat loss encountered with storage tank heaters This water heater does not store water making an insulation blanket unnecessary The manufacturer s warranty does not cover any damage or defect caused...

Страница 24: ...sufficient for the water heater Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Soap and water solution used to check all connections and fittings for...

Страница 25: ...and all other labels on the water heater as well as the warnings printed in this manual Failure to do so can result in unsafe operation of the water heater resulting in property damage personal injur...

Страница 26: ...alves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines Contact a licensed plumber or the local plumbing authority for further information Se...

Страница 27: ...otter water increases the risk of scald injury Always supervise young children or others who are incapacitated The water heater is equipped with a device that will shut off the gas supply to the burne...

Страница 28: ...nance and or cleaning ensure proper operation by turning on a hot water faucet Housekeeping Before performing Housekeeping tasks to this water heater turn the unit off and disconnect the power supply...

Страница 29: ...t It is recommended that qualified service personnel familiar with Category III venting inspect the venting system Check vent connection joint sections with a solution of soapy water to assure air tig...

Страница 30: ...freezing conditions even for a short period of time be sure to drain all water from the unit as instructed above Exposure to freezing conditions can occur from down draft of venting system or from in...

Страница 31: ...functions if applicable Check and replace if necessary Error code displayed on remote control See instructions for Error Code and if required contact a dealer for service Not enough water demand Incre...

Страница 32: ...r safety devices Refer repairs to qualified service personnel CAUTION Make certain power to water heater is OFF before removing protective cover FOR ANY REASON CAUTION Label all wires prior to disconn...

Страница 33: ...33...

Страница 34: ...splay of the Main Remote Control is on continuously Change the DIP Switch 4 setting back to the OFF position DO NOT alter any other DIP Switch The LED on the PCB will stop illuminating At the same tim...

Страница 35: ...35 Notes...

Страница 36: ...ll be located in the room that houses the appliance or equipment and shall a Be powered by the same electrical circuit as the appliance or equipment such that only one service switch services both the...

Отзывы: