COMMISSIONING

All water heaters are tested and adjusted before dispatch, however further

adjustments may become necessary because of local conditions.

TO TURN  ON THE WATER HEATER

Open all of the hot taps in the house (don’t forget the shower). Open the cold water

isolation valve fully. Air will be forced out of the taps. As water flows freely from each

tap, close it.

Open the gas isolation valve fully. Plug the water heater in and switch the power

outlet on. The water heater will now operate when a hot tap is opened.

Check to ensure the flow from each connected hot tap is sufficient to operate the

water heater. The minimum operating flow rate for all models is 3 litres per minute.

The automatic water governor incorporated in the water heater is not adjustable.

GAS INLET PRESSURE

IMPORTANT - CHECK 

the gas supply pressure at the inlet to the water heater with

the water heater and all other gas burning appliances in the premises operating

(burners alight). The minimum gas supply pressures are:

   Natural Gas       1.13 kPa            Propane       2.75 kPa.

If this minimum cannot be achieved, it may indicate the meter or the supply pipe to

the water heater is undersized.

BURNER GAS PRESSURE

It is necessary to check the burner gas pressure at both the minimum and maximum

operational settings. The hot water must be flowing and the burners on to check and

if necessary adjust the operational gas pressures.

Ensure the burners are not operating. Close any hot taps and turn off the gas

supply at the gas isolation valve.

Remove the screws holding the front panel to the jacket.

Gently disengage the front panel and pull forward to disengage from the flue

terminal.

Locate the burner pressure test point on the main burner manifold and connect a

manometer.

Turn on the gas supply at the gas isolation valve.

Содержание 871 018

Страница 1: ...1 Owners Guide and Installation Instructions This water heater must be installed and serviced by an authorised person Please leave this guide with the householder...

Страница 2: ...of Rheem Australia Limited Southcorp Australia Pty Ltd or Paloma Industries Ltd Southcorp Water Heaters Australia is the supplier of the Rheem integrity range of electronic instantaneous gas water he...

Страница 3: ...installer but may be of interest About your water heater 4 Temperature control 7 Save a service call 14 Installation Water heater 16 Dimensions 18 Connections Plumbing 19 Connections Electrical 19 Com...

Страница 4: ...corp Water Heaters Australia or their Accredited Service Agent HOTTER WATER INCREASES THE RISK OF SCALD INJURY We recommend and it may also be required by regulations that an approved temperature limi...

Страница 5: ...air inlet are not obstructed in any way at any time The water heater should be serviced annually by Southcorp Water Heaters Australia or their Accredited Service Agent Only genuine replacement parts s...

Страница 6: ...ater Damage caused by freezing due to the unavailability of power at the water heater is not covered by warranty Pipe work to and from the water heater must be adequately insulated to prevent freezing...

Страница 7: ...the preset outlet temperature Other manufacturers controllers cannot be installed with this water heater TEMPERATURE ADJUSTMENT A controller must be on and have priority to be able to adjust the temp...

Страница 8: ...rrent temperature setting is displayed on all controllers whether hot water is flowing or not when any controller is on If all controllers are off then the display remains blank The water volume can a...

Страница 9: ...9 TEMPERATURE CONTROL BATHROOM CONTROLLER KITCHEN CONTROLLER...

Страница 10: ...ature Adjustment on page 7 The selected temperature setting will be displayed on all controllers 4 Open the hot tap The in use light will glow on all controllers 5 Close the hot tap The in use light w...

Страница 11: ...up button or down button Refer to Temperature Adjustment on page 7 The selected temperature setting will be displayed on all controllers 3 Open the hot tap The in use light will glow on all controlle...

Страница 12: ...e Each press of the up button or down button will change the water volume setting by 10 litres Pressing the up button or down button continuously will scroll the water volume setting Fifteen seconds a...

Страница 13: ...ile water is being drawn press the water volume button After a few seconds the display returns to the temperature setting To turn off the water volume function before the alarm sounds press the water...

Страница 14: ...lation valve in the gas line open Is there a gas supply to the rest of the house Try lighting another gas appliance Has the gas line been purged of air after installation Refer to your plumber WATER I...

Страница 15: ...the cold water supply pipe to the water heater refer to Water Supply on page 17 HIGH GAS BILLS Is one outlet especially the shower using more hot water than you think Carefully review the family s ho...

Страница 16: ...eater dimensions are shown on page 18 The installation must comply with these installation instructions and with the requirements of AS NZS 3500 4 AS 5601 AG 601 and any other statutory requirements I...

Страница 17: ...e for installation in areas where the ambient temperature falls below 20 C including wind chill factor WATER SUPPLY Where the water supply pressure exceeds that shown below an approved pressure limiti...

Страница 18: ...union PIPE INSULATION Adequate insulation is required on the cold and hot pipes to the underside of the water heater in frost prone areas refer to AS NZS 3500 GAS INLET The gas supply pipe is to be f...

Страница 19: ...union must be fitted on the cold water supply pipe before the water heater refer to page 18 Do not fit a non return valve or stop cock The cold water supply pipe should be sized to ensure adequate flo...

Страница 20: ...TANT CHECK the gas supply pressure at the inlet to the water heater with the water heater and all other gas burning appliances in the premises operating burners alight The minimum gas supply pressures...

Страница 21: ...r an error code refer to Error Code on page 15 Maximum test point gas pressure Refer to the rating label on the water heater for the maximum test point gas pressure Follow Steps 1 to 7 above but open...

Страница 22: ...available from Rheem Alternatively the cables may be extended using two core flex with a minimum cross sectional area of 0 5 mm2 No other manufacturers controllers are suitable for connection to this...

Страница 23: ...cable to the two terminals on the back of the controller not polarity sensitive Ensure the connecting screws are seated tightly 7 Place the controller over the base plate Ensure the projections in the...

Страница 24: ...and the water heater 3 Remove the base plate from the controller 4 Peel off one side of the adhesive paper from the foam packing and adhere to the back face of the base plate This is the side without...

Страница 25: ...the cables into the cable notches Failure to do this may cause an unstable contact or even disconnection of the cables from the terminals if the cables were to be pulled 6 Refit the electrical cover t...

Страница 26: ...26 INSTALLATION DIAGRAMS INSTALLATION KITCHEN AND BATHROOM CONTROLLERS INSTALLATION KITCHEN CONTROLLER ONLY INSTALLATION BATHROOM CONTROLLERS ONLY MAX...

Страница 27: ...ntal effects on the water heater and its operation and or life expectancy If you are unsure of your water quality you can obtain information from your local water supply authority This water heater is...

Страница 28: ...er than a single family domestic dwelling All models Year 1 New water heater at Southcorp s sole discretion or component free of charge including labour Water heater installed in a single family domes...

Отзывы: