![Rheem 325 II Series Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/rheem/325-ii-series/325-ii-series_service-instructions-manual_1451475064.webp)
64
This document is stored and maintained electronically by
Service. All printed copies are deemed uncontrolled.
TM077: 325 & 410 Series II Heat Pump Service Instructions
Rev 00: Issued April 2014
Circulator
1.
Drain the water heater
. Refer to „Draining the Water Heater‟ on page 56
2. Remove the heat pump module access panel.
3. Disconnect the circulator plug from the controller.
4. Undo the (large) water connections at the circulator.
5. Remove the circulator from the heat pump module.
6. Replace the washers in the circulator union assemblies.
7. Reassemble in the reverse order of above.
Compressor Sensor
1.
Isolate power to the water heater.
2. For AquaMax storage tanks, remove the heat pump module. Follow steps 6
– 8 of the
„Heat Pump Module Removal‟ procedure on page 62.
3.
Remove the storage tank upper electrical access cover and confirm with a multi-
meter across thermostat terminals 1 and 3 that voltage is not present.
4. Follow steps 6
– 8 of the „Heat Pump Module Removal‟ procedure on page 62.
5. Remove the heat pump module access panel.
6. Disconnect the compressor sensor plug from the controller.
7. Release the sensor cable from its fixings.
8. Gently peel back the discharge pipe insulation to reveal the sensor.
9. Unclip the sensor from the discharge pipe.
10. Reassemble in reverse order of above.
Evaporator Sensor
1.
Isolate power to the water heater.
2. For AquaMax storage tanks, remove the heat pump module. Follow steps 6
– 8 of the
„Heat Pump Module Removal‟ procedure on page 62.
3.
Remove the storage tank upper electrical access cover and confirm with a multi-
meter across thermostat terminals 1 and 3 that voltage is not present.
4. Follow steps 6
– 8 of the „Heat Pump Module Removal‟ procedure on page 62.
5. Remove the heat pump module access panel.
6. Disconnect the evaporator sensor plug from the controller.
7. Release the sensor cable from its fixings.
8. Pull the clip retaining the sensor in the evaporator
coil and gently slide out of the evaporator.
9. Refit the evaporator sensor and clip into the
evaporator coil.
Note:
The sensor must be
positioned in the evaporator in the correct location
(refer to the diagram opposite).
10. Reassemble in reverse order of above.