RGB Technology ZB20 Скачать руководство пользователя страница 3

 

16.02.2016r. 

 

1

 

Specifications 

ZB20 clock 

Display format: HH:MM:SS 
Power supply: 230VAC* 
Control method: IR remote control unit**/ Web Panel 
Digit height: 200mm 
Dimensions of the device: 900 x 288 x 45mm 
Weight of the device: 4kg 
Casing tightness rating: IP66 
Average power consumption of the device: 20W 
Device operation temperature: -20 +60°C 
Available LED colours with their catalogue index number: 

Catalogue index number 

Colour 

301-09-01 

Red 

301-09-02 

Green 

301-09-03 

Blue 

301-09-04 

Yellow 

301-09-05 

Amber 

301-09-06 

White 

Table 1 

*

 

- Optionally,  24VDC power supply also available 

** - IR control module optionally available   

2

 

Transport and storage 

Care  should  be  taken  to  properly  protect  the  devices  so  as  to  eliminate  any  damage  during  transport.  It  is 
forbidden to transport the devices in a collective package without adequate amortisation - each device must be 
packed separately and cannot have freedom of movement during transportation.  

The  module  should  be  stored  in  the  temperature  not  lower  than  -20°C  and  not  higher  than  +60°C  at  the 
humidity below 99%RH.      

3

 

Device construction  

ZB20  has  a  housing  made  of  polycarbonate,  which  is  resistant  to  UV  radiation  and  has  a  high  mechanical 
strength. By using the thermo-moulded housing and a rear sealing layer, the device, when properly assembled, 
meets the IP66 tightness requirements. The display can also operate at the temperatures from -20 ° C to + 60 ° C. 

Содержание ZB20

Страница 1: ...TECHNICAL DOCUMENTATION ZB20 CLOCKS in the Prestige line casing Catalogue index no 301 09 XX Explanatory figure ...

Страница 2: ... configuration 5 4 2 1 Configuration of the device through the embedded website Web panel 5 5 Compact clock extender module 6 5 1 Description of the compact clock extender connectors 6 6 Automatic brightness control of the device 6 7 Executive relay module 6 7 1 Executive relay parameters 6 8 Additional options 7 8 1 IR remote control unit 7 8 2 PoE power supply 7 8 3 GPS module 7 8 4 Temperature ...

Страница 3: ...ionally available 2 Transport and storage Care should be taken to properly protect the devices so as to eliminate any damage during transport It is forbidden to transport the devices in a collective package without adequate amortisation each device must be packed separately and cannot have freedom of movement during transportation The module should be stored in the temperature not lower than 20 C ...

Страница 4: ... power supply unit det F Prestige Line casing det G viewfinder det H M5 cage nuts det I lighting sensor det J IR sensor Fig 1 Explanatory figure 3 1 1 List of display cables 1 Two metre power cord 2 x 0 5mm terminated with power plug 3 2 Dimensions of the ZB20 device All the dimensions shown in the drawings are given in mm Fig 2 3 2 1 Mounting the ZB20 device Fig 3 ...

Страница 5: ...gured using LAN 4 2 ZB20 configuration The configuration process consists in personalising the device through the embedded Web panel The user after connecting the clock through the LAN inteface can edit the display parameters of the clock 4 2 1 Configuration of the device through the embedded website Web panel To connect with the clock first you should configure the network card of the computer to...

Страница 6: ...pply for GPS and thermometer GND Mass of the system Table 2 6 Automatic brightness control of the device In the standard version a lighting sensor is included The device in response to the intensity of daylight adjusts the brightness of the clock display 7 Executive relay module The device is equipped with an embedded executive relay which enables signalling up to 30 alarms The duration of each al...

Страница 7: ...ble in the DTR documentation of the GPS module 8 4 Temperature sensor The temperature sensor Fig 6 is available with two versions of a signal cable length 0 5m and 2m The probe enables measuring and displaying temperature only in C Celsius The detailed description of the temperature probe is available in the DTR documentation according to the catalogue index number Fig 6 8 5 Audible signalling dev...

Отзывы: