6
16.02.2016r.
5
Compact-clock extender module
The extender module (Fig. 4) enables the operation of peripheral devices and, thanks to a battery, ensures correct
time counting when there is no external power supply.
det. A
signal LEDS;
det. B
– relay;
det. C
– relay connector;
det. D
– PoE output ;
det. E
– LAN connector;
det. F
– GPS
connector;
det. G
– temperature probe connector;
det. H
– battery.
Fig. 4
5.1
Description of the compact-clock extender connectors
Symbol
Function
Remarks
RA, RB
Relay (alarm signalling device)
Closing contact, normally open; permissible load:
- resistive:
5 A 250 VAC, 5A 30 VDC
- inductive:
2 A 250 VAC, 2A 30 VDC
TX+
Ethernet
Pin no. 1 plugs RJ–45
TX-
Pin no. 2 plugs RJ–45
RX+
Pin no. 3 plugs RJ–45
RX-
Pin no. 6 plugs RJ–45
POE1, POE2
Linie PoE (Power over Ethernet) lines
According to the IEEE 802.3at standard (PoE+ active power
supply)
GPS
GPS module signal
Cooperates with GPS GM-2
TEM
Thermometer
–
5V
Power supply for external modules
Power supply for GPS and thermometer
GND
Mass of the system
–
Table 2
6
Automatic brightness control of the device
In the standard version, a lighting sensor is included. The device, in response to the intensity of daylight, adjusts
the brightness of the clock display.
7
Executive relay module
The device is equipped with an embedded executive relay, which enables signalling up to 30 alarms. The duration
of each alarm can be set in a time interval between 1 and 59 seconds. Sample applications:
1)
Activating an acoustic signalling device for industrial applications*, signalling, for example, a break or a shift
rotation in an industrial plant;
2)
Activating a school bell;
3)
Giving a time signal to separate systems or devices.
* - optionally, an audible signalling device is available
7.1
Executive relay parameters
Embedded executive relay parameters
Types of contacts
NO (normal open)
Maximum load
5A
Maximum applied voltage
230V
Maximum applied power
1000W
Table 3
There is a possibility to connect a different signalling device (e.g. visual or visual-acoustic) to the relay connector. In