Additional options
8.1
IR remote control unit
IR remote control unit (Fig. 5), catalogue index number 300-03-09, enables entering the embedded user menu.
You can do it by pressing the „
MENU
” button (Fig.5, det. C)
Fig. 5
det. A
– arrows for changing the parameters (UP/DOWN);
det. B
– proceeding to the next position (BACK/NEXT)
det. C
– „MENU” button.
The detailed description of the user menu functions is available in the DTR manual of this device.
8.2
PoE power supply
Optionally, the clock can be powered-up through the LAN connector (PoE). Choosing this power supply option
requires using a power supply device meeting the IEEE 802.3at standard.
8.3
GPS module
Optionally, the device may be equipped with an external GPS module. The properly configured clock equipped
with the GPS module can synchronise the displayed data with a satellite. The detailed description of the module
is available in the DTR documentation of the GPS module.
8.4
Temperature sensor
The temperature sensor (Fig. 6) is available with two versions of a signal cable length 0.5m and 2m..
The probe enables measuring and displaying temperature only in °C (Celsius). The detailed description of the
temperature probe is available in the DTR documentation according to the catalogue index number.
Fig. 6
8.5
Audible signalling device
Optionally, the device is equipped with an audible signalling device. The user may choose one of two signalling
device versions:
1)
volume of the audio signal at the level of 88dB;
2)
volume of the audio signal at the level of 108dB.
The detailed description of the signalling device is available in the DTR documentation according to the
catalogue index number.
9
Initial start-up
Step 1: Connect the device to 230V power supply,
Step 2: Properly connected system should display pre-set (current) time and date.
10
Most common installation errors
1.
Device installed contrary to the instructions,
2.
Drilling additional holes in the casing.
3.
No plugs in unused holes of the extender box.