DEVICE OPERATION MANUAL 

ZA, ZB and ZAH, ZBH Series Clock 

1.

 

Introduction 

 
The devices of ZA, ZB and ZAH, ZBH series are compact clocks with various configuration options. An intuitive user menu operated by a 
remote control allows you to fully customise the device. 
The  clock  equipped  with  a  network  communication  module  allows  remote  configuration  through  the  “Website”  and  time 
synchronization using the Internet time servers. 
 

The clock enables: 

 

adjusting the time of the presentation: the clock, the date, and the temperature,  

 

adjusting the date format and the time format (12-hour or 24-hour), 

 

automatic and manual brightness control,  

 

working in the ECO mode allowing you to reduce power consumption, 

 

 signaling  30 alarms through a built-in transmitter,  

 

choosing the shape of the display font,  

 

automatic time change from the standard time to the daylight saving time and from the daylight saving time to the standard time 

for various locations (Europe, Australia, the United States of America, Canada, Israel), 

 

GPS time synchronization (available with GPS option),    

 

synchronization using the NTP Internet servers (function available in the Ethernet option, requires the Internet access),  

 

Master Mode – a local time server compatible with NTP (function available in the Ethernet option, does not require the Internet 

access),  

 

synchronization with the local “Master Mode” server (function available in the Ethernet option, does not require the Internet 

access),   

 

configuration through the built-in “Website” (function available in the Ethernet option, does not require the Internet access). 

 

Display (content) synchronization in 3 modes (master, basic slave – master transmits only display information, full slave –  master 

transmits display information and temperature) between any types of clocks (the function available in the Ethernet option, 

requires the access to the local network), 

 

setting a unit of measurement for the displayed temperature (Celsius degrees or Fahrenheit degrees), 

 

setting temperature offset, 

 

setting an individual clock name (the function available in the Ethernet option, requires the access to the local network), 

 

setting a language of WWW page (English or Polish, the function available in the Ethernet option, requires the access to the local 

network), 

 

stopwatch function, a timer counting up and a timer counting down. The end of counting is signalled by a built-in relay. 

2.

 

Clock connectors  

Fig. 1 

shows the device connectors that are available after removing the housing cover.   

NOTE! 

Removing the housing cover should be carried out with the power disconnected. This task must be performed with caution.    

Содержание ZA series

Страница 1: ...ocal time server compatible with NTP function available in the Ethernet option does not require the Internet access synchronization with the local Master Mode server function available in the Ethernet option does not require the Internet access configuration through the built in Website function available in the Ethernet option does not require the Internet access Display content synchronization i...

Страница 2: ...ines Power over Ethernet Compatible with standard IEEE 802 3at PoE phantom active power GPS GPS module signal Works with GPS GM 2 TEM Thermometer 5V Power supply for the external modules Power supply for the GPS and the thermometer GND System ground 3 Configuring the clock using the menu The basic configuration method is by means of the remote control through the user menu Fig 2 shows the remote c...

Страница 3: ...arameter which is being modified NOTE To ensure that your device makes automatic changes between the daylight saving time and the standard time correctly you should properly configure the time zone and activate taking into account the daylight saving time NOTE When you set the clock on the last Sunday in March or on the last Sunday in October take into account the information included in point 4 D...

Страница 4: ...in menu press the key NOTE Before setting time from the website the menu or automatically configure regional settings NOTE The satellite synchronization requires the GPS module The network synchronization requires the network module and the Internet access NOTE The Master Mode cannot be activated if the reference clock does not have the active GPS or NTP synchronization To activate the automatic d...

Страница 5: ...with the key 5 Using the and keys modify the value of the entered time of deactivating the clock display next confirm it with the key 6 The clock will return to the main menu to exit the main menu press the key NOTE When the ECO mode is active ECO Y and the time of activating and deactivating the clock is the same the clock will be on for 24 hours To change the display font shape you should 1 Call...

Страница 6: ...unconnected GP NO GPS no signal GP PS GPS poor signal GP GS GPS good signal To configure the clock location the time zone taking into account the daylight saving time you should 1 Call the configuration menu by pressing the MENU key 2 Select the F13 function using the and keys and confirm it with the key 3 Using the and keys select the clock location and confirm it with the key LO EU location Euro...

Страница 7: ...7 ...

Страница 8: ...y function such as counting exiting the F14 menu and re entering the F14 menu and selecting another function will stop counting and cause erasing the counter NOTE Setting the timer counting values is possible only when the timers are stopped In addition setting the counting value to 00 00 or 00 00 00 depending on the clock type causes looping and resetting the counting value protection against the...

Страница 9: ...d to the standard time b Australia the standard time is changed to the daylight saving time on the first Sunday in October at 2 00 AM of the local time adding one hour the daylight saving time is changed to the standard time on the first Sunday in April at 3 00 AM of the local time taking into account DST taking away one hour The daylight saving time is not applied in North Australia Queensland an...

Страница 10: ...configure various functions of the device NOTE Always confirm the changes of the settings of the device parameters with the Save button 2 1 Time tab This tab allows you to configure the parameters connected with time Local date time manual setting of the local time and date Remote time synchronization configuration of the remote synchronization of time of the time zone of allowing for daylight sav...

Страница 11: ...llow set inactive green set active 2 4 Advanced tab This tab allows you to configure the advanced parameters of the device Clock name an individual clock name Network network settings the IP address the subnet mask the default gateway Password setting the user password Default settings restores the factory settings NOTE The Default settings function fully restores the factory settings including re...

Страница 12: ... configuration Master clock Master Slave clock Slave Master Mode active inactive Synchronization source GPS or Ethernet Ethernet Comments When you choose the Ethernet as the synchronization source the Time server boxes from 1 to 5 should include sever addresses compatible with NTP In the Time server box 1 you should enter the master clock Master IP address The Time server IP boxes from 2 to 5 shou...

Отзывы: