An example of a misaligned wall setup without any compensation for the
mullion area is shown in Figure 4-4.
Figure 4-4.
Wall misalignment due to mullions
The figure shows the dislocation error or offset in diagonal lines crossing
the mullion between cubes. Note that only the 2 x 2 walls have both
vertical and horizontal mullions. The linear (1 x 2, 1 x 3, 1 x 4) walls
have only vertical mullions.
An estimation of the mullion width in pixels can be obtained by
measuring the size of the outside dimension of the cube and the
physical dimension of the active area. The mullion width = cube exterior
dimension/active area dimension x number of pixels.
Both mullions and overlap use the same entry boxes. If you enter a
positive number, this is a mullion compensation and the entry box labels
display
Mullion X
and
Mullion Y
. If you enter a negative number, this is
an overlap compensation and the entry box labels display
Overlap X
and
Overlap Y
.
The
MediaWall 2000
mullion and overlap compensation is provided on
the WCP
Setup Configuration
page as shown in the following figures.
Figure 4-5.
WCP Configuration page - Mullions