Set the old thermostatic valve to the
highest setting (e.g. 5) .
1
Place the backplate of Vicki on the
thermostatic valve.
1
Screw tightly the securing ring. Do it by
hand, no special instruments required.
Do not overscrew.
2
Unscrew the securing ring and
remove the thermostat.
2
2
2
1
1
3
Remove the old thermostatic valve.
Mount Vicki on the thermostatic valve
Insert Vicki on the backplate.
3
Installation
Warning:
If you already have a
thermostatic valve, during installation
no water will leak. If you don't have a
thermostatic valve, please call a
specialist and ask them to replace
your valves.
thermostatic valve
Apply moderate pressure with your
palm on Vicki's display and rotate the
device clockwise to secure it on the
backplate.
4
After succesfully mounting of Vicki the
front display must show the callibration
animation.
5
display
animation