1800MHz-1900MHz Off-Air Repeaters (OR Series)
Page
91 080 0701F – Rel.04
CHAPTER 4
4.4
•
AC POWERED EQUIPMENT (ALTERNATE CURRENT)
-
Connect the 230Vac power cable to the connector located on the bottom of the repeater (
ref. 54
,
FIGURE 3). The connector pin assignments is detailed in Table 2.
230Vac POWER SUPPLY CONNECTOR
PIN
CABLE
230VAC POWER SUPPLY
CABLE COLOR
1 LINE
BROWN
2 NEUTRAL
BLUE
3
GROUND (GND)
YELLOW / GREEN
4 NOT
CONNECTED
TABLE 2 – 230Vac POWER SUPPLY CONNECTOR PIN-OUT
-
Connect the other end of the cable to the power supply source (230Vac).
-
Also connect the 48Vdc power and alarms cable, provided standard, to the 15-pin connector located on
the bottom of the equipment (
ref. 55
, FIGURE 3).
The cable makes remote signals available. The connector pin-out is detailed into table 1.
The cable can also be connected to a 48Vdc power supply, to feed the equipment with a D.C. voltage.
PLEASE NOTE:
The 48Vdc power supply cable (also including the external alarms), provided standard with the
equipment, must never be longer than 3 meters in length (connectors included).