1800MHz-1900MHz Off-Air Repeaters (OR Series)
Page
91 080 0701F – Rel.04
CHAPTER 4
4.3
•
D.C. POWERED EQUIPMENT
-
Connect the 15-pole (f) connector on the bottom of the repeater (
ref. 55
, FIGURE 3) to the 48Vdc/Alarm
cable (supplied with the equipment).
The cable permits D.C power supply (48Vdc) to the equipment. It also makes available the remote
signals detailed into Table 1.
-
Connect the cable to the power supply source (48Vdc) and connect the external signals.
PLEASE NOTE:
The 48Vdc power supply cable (also including the external alarms), provided standard with the
equipment, must never be longer than 3 meters in length (connectors included).
48Vdc POWER SUPPLY AND EXTERNAL ALARMS CONNECTOR
PIN
TYPE OF SIGNAL
WIRES COLOR OF 48VDC
POWER SUPPLY AND
EXTERNAL ALARMS
CABLE
0 0Vdc
RED
1 0Vdc
RED
2 -
48Vdc
BLACK
3
48Vdc
POWER SUPPLY
- 48Vdc
BLACK
4
EXTERNAL ALARM 3
GRAY
5
EXTERNAL ALARM 4
BROWN
6
EXTERNAL ALARM 2
ORANGE
7
EXTERNAL ALARM 1
PINK
8
GROUND - GND
GREEN
9
EXTERNAL ALARMS
+5Vdc EXT. ALM.
COMMON
WHITE
10 NOT
CONNECTED
11 BLUE
12
SPV CARRIER FOR BDAs
(IF ANY)
132kHz
VIOLET
13 NOT
CONNECTED
14 NOT
CONNECTED
TABLE 1 – 48Vdc POWER SUPPLY AND REMOTE SIGNALS CONNECTOR PIN-OUT