RFL C37.94FSU
RFL Electronics Inc.
May 20, 2013
16
(973) 334-3100
Table 5. Controls and indicators, Fiber Service Unit (107460-5 and 107460-5-1)
Location
Reference
Designation
Function
Front Panel
U8
Fiber optic detector
SW1
8-position DIP switch used to set FSU operating parameters as follows:
SW1-1 through SW1-4: Selects Data Rate in accordance with Table 6.
SW1-5: Selects CRC generation as follows:
Down = Generate CRC4
Up = Do not generate CRC4
SW1-6: Selects AMI or HDB3 encoding as follows:
Down = Selects HDB3 encoding
Up = Selects AMI encoding
SW1-7: Enables or disables fiber Loopback as follows:
Up = Loopback enabled
Down = Loopback disabled
SW1-8: Enables or disables E1Loopback as follows:
Up = Loopback Enabled
Down = Loopback Disabled
DS1
FO D LED (green) Lights green when fiber optic data is being received.
DS2
FO Y LED (yellow) Lights yellow when remote fiber unit is not receiving data.
DS3
PWR LED (green) Lights green when power is applied to input terminals.
DS4
Fiber Optic Emitter
DS6
E1 Y LED (yellow) Lights yellow when the remote E1 unit is not receiving data.
DS7
E1 D LED (green) Lights green when E1 data is being received.
J204
DB-15 120 ohm E1 Connector
J206
75 ohm E1 TX Connector
J207
75 ohm E1 RX Connector
Rear Panel
TB1
Input power connector (Cdc supply to +SB, connect –dc supply to –
SB)
Ground Lug
Ground lug (Connect to earth ground)
On ECB
No. 107463-5
Board A
F1
FSU power supply fuse (see note below)
Note:
F1 is a 0.25 Amp, 250 Volt SLO-BLO, 5x20 mm fuse.
Littlefuse part number is:
239.250
BUS part number is:
GMD-.25A