pcProx
®
and AIR ID
®
Enroll Readers
Send FAC code
Selecting this checkbox will cause the FAC code
to be sent.
Force data to length
This applies to both Facility and ID code data
fields. Zeroes are added to the front of the data
to create a specific length. For example, if the
data were 567 and the length is set to 6, the
output will be 000567.
FAC fixed to this length
Zeroes are added to the front of the FAC portion
of the data to create a specific length.
Send ID Code
Since there are two fields of data (ID and FAC)
and sending at least one is necessary, this field
really implies send the ID and not the FAC data.
If both fields need to be sent, you need to select
the ‘Send the FAC code’ checkbox.
Bit count of ID portion only
This field is used to define the bit count of ID
portion of the card data. To retrieve this data
properly, you will need to also indicate and strip
the Leading and Trailing parity bits.
ID fixed to this length
Zeroes are added to the front of the ID portion of
the data to create a specific length.
Enable FAC/ID character
This checkbox indicates that a separator
character will be used between the FAC and ID
codes.
This char sent between FAC & ID
This field holds the character that will be placed
between the FAC and ID codes. Note there are