Rev 7.21
4
3.0 Serial Port Commands
3.1 To 8050E (Antenna controller)
3.1.1 [1CXX]
Format: 1 = Start or End Char Command, C = Defines Start or End character, XX = hex value
Valid values: C = ‘S’ or ‘E’, XX = a Hex value. Values outside of ASCII letters and numbers are
recommended
Response: OK
Example 1: [1S0A] sets the start character as a Line Feed
Example 2: [1E0D] sets the end character as a Carriage Return
Example 3: [1S00] sets the start character to none
3.1.2 [2NNOO]
– Change Reader Address
Format: 2 = Set Reader CAN address, NN = New CAN address, OO = Current (old) CAN address
Valid Addresses: 01 to 32
Response: OK, FAILED1, or FAILED2
Example: [23001] change Reader from address #01 to address #30
Example response 1: OK = #01 existed on the CAN bus and has been reset to #30
Example response 2: FAILED1 = #01 does not exist on the bus
Example response 3: FAILED2 = #30 is already in use
3.1.3 [3]
Format: 3 = Scan for present readers
Response: RDR1, RDR2, RDRn…
Example: [3] Request a scan of present readers
Example response 01 07 19 31
All commands are ignored while scanning for readers, when the scan is finished the interface will
send a Carriage return to indicate so.
3.1.4 [4=IP address]**
Format: 4=NNN.NNN.NNN.NNN
Response: OK
Example: [4=10.0.1.42] Set new IP address
3.1.5 [5=Mask]**
Format: 5=NNN.NNN.NNN.NNN
Response: OK
Example: [5=255.255.255.0] Set new subnet mask
3.1.6 [6=Gateway]**
Format: 6=NNN.NNN.NNN.NNN
Response: OK
Example: [6=10.0.1.1] Set new gateway
**NOTE: Not applicable to interfaces using XPORT