Model No: RFAS8810 

8 IN 8 OUT 

Programmable Attenuator Subsystem 

 
 
 

 

 
 

 

                                 

 

 

 

 

Содержание RFAS8810

Страница 1: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 1 Model No RFAS8810 8 IN 8 OUT Programmable Attenuator Subsystem...

Страница 2: ...s Setting 8 3 Remote Local Setting 8 4 Single channel Attenuation Setting 9 5 Multiple channel Attenuation Setting 11 6 All Channel Attenuation Setting 12 7 IP Address Change 13 REMOTE CONTROL 14 1 Po...

Страница 3: ...mmunication users can write PC control programs in VBScript under the RS232 serial communication protocol 3 The programmable test subsystem can simplify test setups such as handover variable handover...

Страница 4: ...Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 4 4 Panel view Front panel Back panel 5 Physical Dimensions units mm in...

Страница 5: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 5 SIGNAL DIAGRAM...

Страница 6: ...m 1 3 1 typical Attenuation Accuracy 0 5 dB 10 dB 1 0 dB 10 31 dB 1 5 dB 32 63 dB 2 5 dB 64 110 dB Insertion Loss 16 dB maximum RF Input Power 30 dBm average Switching Speed 2 us typical AC Supply 100...

Страница 7: ...USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 7 LOCAL CONTROL 1 Power On When the power comes on the following boot screen displays Figure 1 Boot Screen After a few seconds you wi...

Страница 8: ...nd notice that the field is now highlighted in blue Type 224 Use the ESC key to cancel mistakes After you finish press F1 to save the setting The remote local setting screen will open Figure 3 Remote...

Страница 9: ...hannel indicated by an asterisk See Figure 6 Press ENTER to return the main screen and the color of active channel will change from black to blue There are two ways to set the attenuation value One wa...

Страница 10: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 10 Figure 5 Channel setting Figure 6 Single Channel Setting...

Страница 11: ...e knob to align the asterisk with an intended channel and then press the knob slightly to select the channel Pressing the knob twice will cause the symbol to disappear meaning no channel is selected I...

Страница 12: ...vance to the channel setting screen To select all channels from the channel setting screen press F3 Figure 9 Return to the main screen and notice that all channels are displayed in blue Figure 9 indic...

Страница 13: ...499 1302 www rflambda com Page 13 Figure 9 All Channel Setting 7 IP Address Change With the main screen in local mode you can verify the current IP address and change the IP address by pressing F3 Fig...

Страница 14: ...972 499 1302 www rflambda com Page 14 REMOTE CONTROL 1 Port Configuration Software Installation Begin by installing the serial port server driver Open the NE 4110S folder and click neadm_setup_Ver2 1...

Страница 15: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 15 Click the Next button The following window opens...

Страница 16: ...LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 16 Click the Next button The following window opens Click Install to open the insta...

Страница 17: ...TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 17 After the installation is complete the following window opens Click Finish to finalize the installation 2 Port Configurat...

Страница 18: ...x 972 499 1302 www rflambda com Page 18 To modify the IP address with the unit connected to the PC via parallel cable begin by opening the Configuration menu and selecting Broadcast Search The system...

Страница 19: ...ouble click on the system whose IP address you want to modify NE 4110S in the illustrated example to open its IP Settings window In the Configuration window select the Network tab check the Modify che...

Страница 20: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 20 To confirm your selections click OK...

Страница 21: ...024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 21 Open Internet Explorer and enter the unit s IP address From the Main Menu open the Serial Settings folder adjust the parameters...

Страница 22: ...972 499 1302 www rflambda com Page 22 From the Main Menu open the Operating Settings folder adjust the parameters as necessary click on Submit to confirm your selections and close IE 3 Operating Softw...

Страница 23: ...860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 23 Read the text on the screen and click on Next to advance to the next screen Do not re...

Страница 24: ...trol Interface Click on the icon 8in8outProgrammableSubsystem exe or choose Start All Programs 8in8out ProgrammableSubsystem exe Because of the test subsystem s access to the LAN the network computer...

Страница 25: ...allas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 25 Clicking on Disconnect will disconnect the communication subsystem Click either or to toggle...

Страница 26: ...e instructions Set single channel attenuation values In the text box next to each channel ANT1 ANT2 ANT3 etc enter the intended channel attenuation value and click Send to confirm your selection Each...

Страница 27: ...767 5998 Fax 972 499 1302 www rflambda com Page 27 Multi channel Attenuation Setting Begin by selecting the channels you intend to set Do this by checking the box to the left of the channel label Then...

Страница 28: ...A Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 28 Road through operational settings Click on Visible Port and select the interface to operate by checking the box next to the interface...

Страница 29: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 29 To customize the name of a channel begin by clicking on Tools...

Страница 30: ...TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 30 The Frm_Tools window opens Click on Profile The Frm_Profile window opens Use the text box next to the channel label to mo...

Страница 31: ...the name will automatically be saved To set an attenuation value for all eight channels simultaneously begin at the 8in8out Programmable Subsystem window Click on Tools As with the channel name custom...

Страница 32: ...lephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 32 To set an initialized value for the attenuation open the Frm_Tools window as in the two previous procedures Choose a value from the Initi...

Страница 33: ...phone 972 767 5998 Fax 972 499 1302 www rflambda com Page 33 Save and return to the main interface when in the Settings drop down list select a channel click on Iinitiallze later In addition to the se...

Страница 34: ...ay Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 34 Click AutoScript run into the automation interface Set the appropriate parameters the first point of Ap...

Страница 35: ...TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 35 Point Pause pause point Quit to exit Other buttons Read All to read the current attenuation value of all channels About Sy...

Страница 36: ...CUSTOM SCRIPT SETTINGS Run automation script From the primary window select Browse and then navigate to the location of the VBScript Begin the script by clicking on Run R Communication protocol can b...

Страница 37: ...rkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 37 ACCESSORIES 1 110V 220V power cable 1pcs 2 CD driver control software user manual 1pcs 3 User manual...

Страница 38: ...Get the output port connected to any input port It is used in a power Combiner system LO Lock keyboard of the system LU Unlock keyboard of the system RT Restart system Enter HX and command without spa...

Страница 39: ...LF Set Switch The set switch command is used to set a switch to a specifi c port number Syntax SSx y CR LF x switch number y port number Example SS11 8 CR LF Sets switch 11 to port 8 System will retu...

Страница 40: ...et the output port connected to any input port It is used in a power Combiner system Syntax ROx CR LF x input port Example RO 1 CR LF Get the output port connected to input 1 System will return RO1 1...

Отзывы: