6.   Servicing & Maintenance

6.1 Maintenance

Always ensure that the main external electricity supply is switched off before 
commencing any maintenance on this heater.

To obtain the best results from the heater, it is essential to avoid the accumulation 
of dust and dirt within the unit on the air inlet and discharge grilles. For this reason 
regular cleaning is necessary.

•  Cleaning of the fan is best carried out with a soft brush.

•  The product should be serviced annually. 

•  Servicing shall be undertaken by a competent person. 

6.2 General

If the heater does not operate a competent service engineer should be called to 
identify the nature of the fault.

All heaters are fitted with motor thermal protection.

Other faults in relation to the element, motor and wiring should be identified using 
conventional fault finding techniques.

In the event that electrical components are replaced, please ensure that electrical 
safety checks in accordance with the regulations in force in the country of use are 
undertaken.

6.3 Thermal cut–out

The units are protected from overheating in the event of fan failure or an obstruction 

of the free airflow, by thermal cut outs. If this happens the thermal cut outs switch off 

the appliance. The appliance will not operate until the heater is disconnected from the 
mains supply and it has cooled down.

If this fault re–occurs again, refer to the section ‘6.4 fault finding’. 

6.4 Fault Finding

If the heater will not operate, disconnect it from the mains and arrange for a certified 

electrician to attend and investigate the reason.

6.5 Replacing the Fan Heater

Please follow the steps below to safely replace the fan heater.

Begin by removing the grille.

1

Disconnect the internal wiring from 

the blower

2

Remove the four screws fixing 

the fan heater assembly to the 

back of the case.

3

The fan heater assembly can 

now be eased forward and 

removed from the heater case.

4

Fit the replacement fan heater.

5

Reassemble in reverse order.

6

Page 9 

Содержание ACT03

Страница 1: ...orce All external wiring MUST comply with the codes of practice or rules in force in the country of installation Improper installation adjustment alteration service or maintenance can cause property d...

Страница 2: ...es 4 2 Dimensions 5 3 Installation Details 6 3 1 Mounting 6 4 Electrical Connections 7 4 1 Electrical Connections 7 4 2 Electrical connections for RX models 7 5 Operation 8 5 1 RX Models ACT 03 04 06...

Страница 3: ...is serviced annually The heater outlet inlet must not be obstructed during use 1 3 Electrical Supply Electrical supply is 230 240V single phase Neutral and Earth The maximum cable inlet size is 4mm It...

Страница 4: ...round the case and 30mm above the heater The clearance allows for cable entry and prevents combustible surfaces overheating The minimum mounting height floor to grille is 2 2m for the ACT03 RX ACT04 R...

Страница 5: ...2 Dimensions ACT 03 04 ACT 06 Page 5...

Страница 6: ...nt to the building are sound Care must be taken to allow complete free air movement into the inlet grilles of the unit to ensure the correct working operation of the heater Carefully unpack the unit T...

Страница 7: ...connection to the mains supply it will be necessary to open the terminal cover at the side back of the unit to connect the supply from the controls prior to refitting the cover Wire in accordance to...

Страница 8: ...rolled by CONSORT wireless controller CRX2 The heaters will not work without a controller Each controller has unique identification code it can control unlimited number of heaters and will not interfe...

Страница 9: ...ase ensure that electrical safety checks in accordance with the regulations in force in the country of use are undertaken 6 3 Thermal cut out The units are protected from overheating in the event of f...

Страница 10: ...l listed is offered subject to the Company s General Conditions of Sale a copy of which can be obtained on request NORTEK GLOBAL HVAC UK LTD Fens Pool Avenue Brierley Hill West Midlands DY5 1QA United...

Отзывы: