![REXROTH HCS02.1 Series Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/rexroth/hcs02-1-series/hcs02-1-series_project-planning-manual_1449567077.webp)
Rexroth IndraDrive C
Electrical Data
6-37
DOK-INDRV*-HCS02.1****-PR02-EN-P
Type
Number of poles
Type of design
Spring power
4
Pins on connector
Fig. 6-46:
Design
Cross section
single-wire
[mm²]
Cross section
multi-wire
[mm²]
Cross section
in AWG
0.14-1.5
0.14-1.5
28-16
Fig. 6-47:
Connection Cross Section
4
+24 V
3
+24 V
2
0 V
1
0 V
Fig. 6-48:
Identification of the individual connections
looping through the power supply
up to max. 6 Aeff allowed
polarity reversal protection
over the allowed voltage range by
internal protective diode of +24V
circuit
Fig. 6-49:
Load capacity
Note:
The input 0 V connected in conductive form with the housing
potential. It is therefore impossible to use an insulation monitor
at +24 V and 0 V against housing.
line cross section
min. 1 mm²
line routing
preferably in parallel
max. allowed inductance between 24V
supply source and X13
100 µH
(corresponds to approx. 2*75 m)
Fig. 6-50:
Supply line 24 V
Design
Connection Cross Section
Connection
Load Capacity
Lines +24 V and 0 V
Содержание HCS02.1 Series