6-6
Electrical Data
Rexroth IndraDrive C
DOK-INDRV*-HCS02.1****-PR02-EN-P
Allowed DC Bus Continuous Power with Single-Phase Mains
Connection
For operation with single-phase mains supply, DC bus continuous powers
according to the diagrams below are allowed.
Note:
Single-phase mains connection via the connections L1 and L2
is only allowed for single-source supply!
Apart from the specified continuous power, there is no peak
power available in the DC bus in the case of single-phase
operation.
0,0
0,2
0,4
0,6
0,8
1,0
1,2
1,4
1,6
1,8
200
250
300
350
400
450
500
U
LN
[V]
P
DC c
o
n
t
[kW
]
W0070
W0054
W0028
W0012
Fig. 6-5:
P
DC_cont
HCS02.1E single-phase