Troubleshooting
Problem
Possible Cause
Action
Frequent tripping
Fault in driven machine
Rectify
Torque setting too low
Adjust trip torque within safe limits
for driving and driven equipment.
All modules not reset
Reset all modules
Worn module plungers or seats
Replace modules
Failure to trip on
overload
Torque setting too high
Adjust trip torque
Module seized
Replace module
Torque limiter bearing seized
Replace bearing
Excessive backlash
Modules loose or incorrectly fitted
Follow installation procedure
Worn module plungers or seats
Replace worn parts
Worn torque limiter bearing
Replace bearing
Worn coupling or loose fasteners
Replace worn parts, tighten