7. Adjust gap to 0.25mm by rotating module body
8. Mark Body and Clamp Collar
9. Remove Clamp Collar Screw
10. Refit Clamp Screw
= Use Loctite 243
d
h
T
Nm
ft.lbf
M5
4
6.7
4.9
11. Fit 4 screws
= Use Loctite 243
d
h
T
Nm ft.lbf
M6
5
11
8
12. Repeat Steps 3 to 11 for remaining modules