background image

 

the charging automatically stoped and red LED on the charger turn off and indicates that the 

battery is fully charged. 

Always  charge  device's  storage  batteries  ONLY  with  the  paired  chargers  to  it.  Thus 

you will prevent damages or confusion b

etween “+” and “-” because the use of other 

chargers or adaptors  may lead to irretrievable damages in the batteries! 

 

 

6

Possible problems during exploitation of “

VEGA

”: 

6.1

.  When  switching  it  on  you  can  not  hear  a  sound,  there  is  no  information  on  the 

display, no indication that the device is switched on. It might indicate for: 

 

- Accumulator battery is dead (usually after a long period of time). Charge the battery 

with  the  charger.  If  the  problem  is  not  solved  contact  the  service-station  (office)  of  the 

company manufacturer or the local distributor. 

 

6.2. 

The working depth is significantly shallower than the normal.  It might indicate for: 

- Accumulator battery could be discharged 

– pay attention to the shown for the capacity of 

the battery. If it is under 

12V,

 charge the batteries with the automatic charger. If you can not 

solve  the  problem  contact  the  service-station  (office)  of  the  company  manufacturer  or  the 

local distributor. 

 

6.3. 

During detection the device does not work stable, makes strange sounds which 

are not due to a metal detection. It might indicate for: 

-irregular electromagnetic external interruptions. 

-problems with the aerial cable 

– disconnected conductor, a shot circuit or bad connection in 

the coupling.  

 

It  is  possible  after  continuance  work  and  many  times  of  switching  on  and  off  the 

cable's  coupling  to  the  jack  box  the  contact  between  them  to  be  destroyed.    There  are  2 

terminals  with  sightholes  in  the  jack  of  the  back  panel  of  the  device.  Put  something  sharp 

like a knife or a screwdriver in the sightholes and make them wider. Thus the coupling will fit 

better  into  the  jack  which  will  improve  the  contact  between  them.  It  is  possible  in  the 

presence of some kind of dirty like dust or moisture to clean the terminals with cotton-wool 

and  alcohol.  If  you  can  not  solve  the  problem  contact  the  service-station  (office)  of  the 

company manufacturer or the local distributor. 

Содержание Vega

Страница 1: ...1 REX TM Metal Detectors V E G A pulse induction metal detector User s guide ____________________________ www rexmetaldetectors com ____________________________ Made in Bulgaria ...

Страница 2: ...ed to adjust threshold level Rotate the controller counter clockwise to low position to avoid interference Clockwise rotate the controller to have high hum level DELAY sampling delay control knob GND DISC dual control knob adjust ground balance in ALL METAL mode and discrimination in DISC mode Button DISC switch on and switch off DISC mode Button MODE toggling between Dynamyc and Static modes Butt...

Страница 3: ...it Finally adjust search coil angle to your preference and you are ready NOTE Do not allow the cable to flop loosely over the search coil Since the detector is sensitive enough to see the tiny wires in the cable a floppy cable can cause false signals as the search coil senses the moving wires When use the search frames 1x1m or bigger The search frame should be held approximately 4 to 6 inch 10 to ...

Страница 4: ...SC knob In ALL METAL mode this knob working as ground balance control Lower the search frame coil to within one inch of the ground surface while listening to the threshold audio signal If the threshold signal increase the GND DISC control needs to be increased to high position At the same time you can increase DELAY too to high position When DELAY knob is in low to middle positions 1 5 detector wi...

Страница 5: ...tion Don t set the THRESHOLD to high position Or you ll get a false result Also low sensitivity usually used when a large object is detected at a small depth in earth Then the signal is continuous in order to determine the exact place of the object it is more convenient to use low sensitivity Thus the signal from the detected object becomes much shorter VEGA can sometimes react by small objects su...

Страница 6: ... less than the maximum depth but at the same time can be eliminated large iron ferrous objects You can set your preference discrimination as to what extent be rejected iron magnetic objects Recommended to work as DISC is 8 In this case loss of depth is not as tangible while successfully eliminating most magnetic objects When the frame moves over a ferrous object the sound level does not change and...

Страница 7: ...n do field tests by yourself using the device if you bury different metal objects in different depth but you should leave them in the ground for at least 3 months Thus the test results will be more reliable You should mind the soil type and the moisture composition in it Best results are received when the soil is dry 5 Charging storage batteries and indications for their status VEGA has a built in...

Страница 8: ... battery If it is under 12V charge the batteries with the automatic charger If you can not solve the problem contact the service station office of the company manufacturer or the local distributor 6 3 During detection the device does not work stable makes strange sounds which are not due to a metal detection It might indicate for irregular electromagnetic external interruptions problems with the a...

Страница 9: ...EGA has been exposed to low temperatures you should absolutey avoid an abrupt warming The condensation humidity can provoke a disturbance of function 7 Guarantee The detector VEGA is offered with 2 years of guarantee of electronics labor and materials used for harms which are not caused on purpose or irresponsibly We can upkeep your device after period of guarantee if it is necessary The Manufactu...

Отзывы: